===Function required=== | ===Function required=== | ||
− | A | + | A selection of intercom stations should, by dialing a number on the keypad, or by pressing a DAK key, be able to pulse a relay for 5 seconds. |
=== Solution === | === Solution === | ||
+ | The stations dial an Event Trigger number 9533 (feature 85) to pulse the [[RCO]] 3 for 5 seconds. | ||
+ | |||
Assign the stations to UDP group 1. | Assign the stations to UDP group 1. | ||
Revision as of 12:02, 7 June 2013
Function required
A selection of intercom stations should, by dialing a number on the keypad, or by pressing a DAK key, be able to pulse a relay for 5 seconds.
Solution
The stations dial an Event Trigger number 9533 (feature 85) to pulse the RCO 3 for 5 seconds.
Assign the stations to UDP group 1.
In AlphaPro, go to Exchange and System -> Events, press Insert and create the following event:
Event 1 - Start a 5 sec. timer when 9533 is dialled.
Event Owner: | Stations w/ UDP Id: 1 |
Event type: | 15 – Event Trigger |
When change to: | ON |
When related to: | Directory Number, Id: 9533 |
Action: | RCO 3 ON 50 |