Revision as of 12:02, 7 June 2013

Function required

A selection of intercom stations should, by dialing a number on the keypad, or by pressing a DAK key, be able to pulse a relay for 5 seconds.

Solution

The stations dial an Event Trigger number 9533 (feature 85) to pulse the RCO 3 for 5 seconds.

Assign the stations to UDP group 1.

In AlphaPro, go to Exchange and System -> Events, press Insert and create the following event:


Event 1 - Start a 5 sec. timer when 9533 is dialled.

Event Owner: Stations w/ UDP Id: 1
Event type: 15 – Event Trigger
When change to: ON
When related to: Directory Number, Id: 9533
Action: RCO 3 ON 50