Pulsing of RCO (Event Handler): Difference between revisions
From Zenitel Wiki
No edit summary |
|||
| Line 3: | Line 3: | ||
=== Solution === | === Solution === | ||
The stations dial an Event Trigger number | The stations dial an Event Trigger number (feature 85), say number 9533, to pulse the [[RCO]] 3 for 5 seconds. | ||
First, assign the stations to UDP group 1. | |||
Second, in [[AlphaPro]], go to [[Exchange_%26_System_%28AlphaPro%29#Events|Exchange and System -> Events]], press Insert and create the following event: | |||
------------ | ------------ | ||
'''Event 1''' - Start a 5 sec. timer when 9533 is dialled. | '''Event 1''' - Start a 5 sec. timer when 9533 is dialled. | ||
Revision as of 12:05, 7 June 2013
Function required
A selection of intercom stations should, by dialing a number on the keypad, or by pressing a DAK key, be able to pulse a relay for 5 seconds.
Solution
The stations dial an Event Trigger number (feature 85), say number 9533, to pulse the RCO 3 for 5 seconds.
First, assign the stations to UDP group 1.
Second, in AlphaPro, go to Exchange and System -> Events, press Insert and create the following event:
Event 1 - Start a 5 sec. timer when 9533 is dialled.
| Event Owner: | Stations w/ UDP Id: 1 |
| Event type: | 15 – Event Trigger |
| When change to: | ON |
| When related to: | Directory Number, Id: 9533 |
| Action: | RCO 3 ON 50 |