Difference between revisions of "Pulsing of RCO (Event Handler)"
From Zenitel Wiki
(→Solution) |
|||
Line 9: | Line 9: | ||
Second, in [[AlphaPro]], go to [[Exchange_%26_System_%28AlphaPro%29#Events|Exchange and System -> Events]], press Insert and create the following event: | Second, in [[AlphaPro]], go to [[Exchange_%26_System_%28AlphaPro%29#Events|Exchange and System -> Events]], press Insert and create the following event: | ||
------------ | ------------ | ||
− | |||
{| | {| | ||
|- | |- |
Revision as of 12:05, 7 June 2013
Function required
A selection of intercom stations should, by dialing a number on the keypad, or by pressing a DAK key, be able to pulse a relay for 5 seconds.
Solution
The stations dial an Event Trigger number (feature 85), say number 9533, to pulse the RCO 3 for 5 seconds.
First, assign the stations to UDP group 1.
Second, in AlphaPro, go to Exchange and System -> Events, press Insert and create the following event:
Event Owner: | Stations w/ UDP Id: 1 |
Event type: | 15 – Event Trigger |
When change to: | ON |
When related to: | Directory Number, Id: 9533 |
Action: | RCO 3 ON 50 |