Pulsing of RCO (Event Handler): Difference between revisions
From Zenitel Wiki
No edit summary |
No edit summary |
||
| Line 3: | Line 3: | ||
=== Solution === | === Solution === | ||
The stations dial an Event Trigger number (feature 85), say number 9533, to pulse the [[RCO]] 3 for 5 seconds. | The stations dial an Event Trigger number ([[Event Trigger with cancel tone feature|feature 85]]), say number 9533, to pulse the [[RCO]] 3 for 5 seconds. | ||
First, assign the stations to [[UDP|UDP group 1]]. | First, assign the stations to [[UDP|UDP group 1]]. | ||
Revision as of 12:14, 7 June 2013
Function required
A selection of intercom stations should, by dialing a number on the keypad, or by pressing a DAK key, be able to pulse a relay for 5 seconds.
Solution
The stations dial an Event Trigger number (feature 85), say number 9533, to pulse the RCO 3 for 5 seconds.
First, assign the stations to UDP group 1.
Second, in AlphaPro, go to Exchange and System -> Events, press Insert and create the following event:
| Event Owner: | Stations w/ UDP Id: 1 |
| Event type: | 15 – Event Trigger |
| When change to: | ON |
| When related to: | Directory Number, Id: 9533 |
| Action: | RCO 3 ON 50 |