Difference between revisions of "AlphaCom XE1"
From Zenitel Wiki
(→Connections=) |
(→Connections) |
||
Line 11: | Line 11: | ||
===<u>Connections</u>=== | ===<u>Connections</u>=== | ||
+ | [[File:XE1 Connections.png|thumb|left|500px]] | ||
+ | <br style="clear:both;" /> | ||
+ | * The exchange is normally powered from the mains via a 5 VDC power supply | ||
* Two RJ-45 Ethernet terminals are used for IP LAN, WAN, Internet and AlphaNet IP communication. Eth0 is also used for programming | * Two RJ-45 Ethernet terminals are used for IP LAN, WAN, Internet and AlphaNet IP communication. Eth0 is also used for programming | ||
+ | * There are two inputs for clean contacts on the [[RCI - Remote Contol Input|RCI connectors]] which can execute programmable functions. Note that the cabinet needs to be opened to get access to these connectors | ||
* The serial ports with RS232 and RS422/RS485 interfaces are used for connecting to equipment using these protocols | * The serial ports with RS232 and RS422/RS485 interfaces are used for connecting to equipment using these protocols | ||
− | * | + | |
− | * | + | ====Serial Ports==== |
− | [[File:XE1 | + | * Serial Port 0 - 9-Pin D-sub (RS232 Only) |
+ | :No additional settings necessary | ||
+ | * Serial Port 1 - RJ45 (RS232/422/485) | ||
+ | :Additional settings: | ||
+ | :'''RS232:''' | ||
+ | :* [[AMC-IP_-_AlphaCom_Processor_Board_(Red)#Switches_and_jumpers|Switch 8 on S601]] on the AMC-IP board must be set to OFF. | ||
+ | |||
+ | :'''RS422/485:''' | ||
+ | :* [[AMC-IP_-_AlphaCom_Processor_Board_(Red)#Switches_and_jumpers|Switch 8 on S601]] on the AMC-IP board must be set to ON. | ||
+ | :* Take off the top lid to reach the jumpers inside, and set them to the correct position. | ||
+ | ::- RS485: Both jumpers in position 2-3 (default) | ||
+ | ::- RS422: Both jumpers in position 1-2 | ||
+ | |||
+ | [[File:SerialPortJumpers XE1.png|thumb|left|500px|RS422/485 selector for Serial Port 1 in the XE1]] | ||
<br style="clear:both;" /> | <br style="clear:both;" /> | ||
+ | |||
[[Category:AlphaCom Servers]] | [[Category:AlphaCom Servers]] |
Revision as of 13:48, 3 November 2016
Highlights
- Made to provide critical communication in any environment
- Supports 552 IP stations
- Environmental friendly and energy saving - max. 4 W
- SIM card based software configuration and disaster recovery
- Fully compatible with any AlphaCom system
Additional Documentation on Zenitel.com
Connections
- The exchange is normally powered from the mains via a 5 VDC power supply
- Two RJ-45 Ethernet terminals are used for IP LAN, WAN, Internet and AlphaNet IP communication. Eth0 is also used for programming
- There are two inputs for clean contacts on the RCI connectors which can execute programmable functions. Note that the cabinet needs to be opened to get access to these connectors
- The serial ports with RS232 and RS422/RS485 interfaces are used for connecting to equipment using these protocols
Serial Ports
- Serial Port 0 - 9-Pin D-sub (RS232 Only)
- No additional settings necessary
- Serial Port 1 - RJ45 (RS232/422/485)
- Additional settings:
- RS232:
- Switch 8 on S601 on the AMC-IP board must be set to OFF.
- RS422/485:
- Switch 8 on S601 on the AMC-IP board must be set to ON.
- Take off the top lid to reach the jumpers inside, and set them to the correct position.
- - RS485: Both jumpers in position 2-3 (default)
- - RS422: Both jumpers in position 1-2