ST STATE: Difference between revisions
From Zenitel Wiki
No edit summary |
No edit summary |
||
| Line 46: | Line 46: | ||
2: RCO 2....<br\> | 2: RCO 2....<br\> | ||
|- | |- | ||
|align=center|8||[[NET_OBJ_REF]]||colspan="3"|( | |align=center|8||[[NET_OBJ_REF]]||colspan="3"|(Empty REF in no conn active)Related station in connection. | ||
|- | |- | ||
|align=center|9||[[UINT2]]||colspan="3"|( | |align=center|9||[[UINT2]]||colspan="3"|(0 if no conn active)Connection reference as given in [[CONN_STATUS_BC]] | ||
|- | |- | ||
|align=center|10||[[UINT1]]||colspan="3"|( | |align=center|10||[[UINT1]]||colspan="3"|(0 if no conn active)CALL status as given in [[CALL_STATUS_BC]] | ||
|- | |||
|align=center|11||[[UINT4]]||colspan="3"| IP station hardware type. <br> | |||
IP HW type ID : <br> | |||
32800 0x8020 IP Dual Display <br\> | |||
32801 0x8021 SUB station board 1 <br\> | |||
32802 0x8022 SUB station board 2 <br\> | |||
32803 0x8023 Console board <br\> | |||
32804 0x8024 IP Desktop <br\> | |||
28708 0x7024 SoftClient <br\> | |||
32806 0x8026 IP-ARIO <br\> | |||
33568 0x8320 PA 1 <br\> | |||
33584 0x8330 PA 2 <br\> | |||
00256 0x0100 SIP Phone <br\> | |||
00257 0x0101 IP Dummy station <br\> | |||
00000 0x0000 Analog station/no station <br\> | |||
|- | |||
|align=center|12||[[UINT1]]||colspan="3"| Station type as defined in AlphaPro <br\> | |||
Station type codes: <br> | |||
0 Master Station <br\> | |||
1 Sub Station <br\> | |||
2 PNCI <br\> | |||
3 CRM station <br\> | |||
4 InterGuard <br\> | |||
5 DualDisplay <br\> | |||
6 Custom <br\> | |||
7 SIP station <br\> | |||
8 Conference Mixer <br\> | |||
|- | |||
|align=center|13||[[UINT4]]||colspan="3"| IPARIO status flags <br> | |||
Bit number: <br> | |||
0 Amplifier 1, fault relay <br> | |||
1 Amplifier 2, fault relay <br> | |||
2 Amplifier 1, 24VDC fault <br> | |||
3 Amplifier 2, 24VDC fault <br> | |||
4 Amplifier 1, Speaker Loop Monitoring 1 <br> | |||
5 Amplifier 2, Speaker Loop Monitoring 2 <br> | |||
6 Amplifier 1, XLR Connected <br> | |||
7 Amplifier 2, XLR Connected <br> | |||
10 IPARIO down <br> | |||
11 $PA_CMD "ACK" <br> | |||
12 --$PA_CMD "CLEAR" <br> | |||
13 Fault led steady. (Fault acknowledged) <br> | |||
14 Fault led blinking. (Fault not acknowledged) <br> | |||
|- | |- | ||
|colspan="2"|Response to:||colspan="3"|[[GET_ST_STATE]] | |colspan="2"|Response to:||colspan="3"|[[GET_ST_STATE]] | ||
Revision as of 07:52, 8 May 2013
| ST_STATE | 0x009A | 154 | AMC 10.23 | |
|---|---|---|---|---|
| Response to the GET_ST_STATE message. | ||||
| Current status of a station <br\> Illegal station or no more stations available will return ST_STATE without parameters | ||||
| 1 | UINT2 | 1 -> 552: Station Physical Number | ||
| 2 | NET_OBJ_REF<br\>{ECL_STATION} | Default user Directory Number | ||
| 3 | TEXT16 | Default user Display text | ||
| 4 | UINT4 | State bitmap Bits:<br\>
1: 0 = Free, 1 = Busy <br\>
2: 0 = A station, 1 = B station in communication.(Param 8. describe related station) <br\>
3: 0 = M-rel, 1 = M-pres <br\>
4: 0 = Hook on, 1 = Hook off <br\>
(*)5: 0 = privat off, 1 = private on <br\>
6: 0 = No mail, 1 = Mail in queue <br\>
7: 0 = Tone test OK, 1 = Failed. (11.1.3.2) | ||
| 5 | UINT1 | Line State <br\>
0 Board not present <br\> 1 SLI board present, no station <br\> 2 SLI board present, station with failure <br\> 3 Station connected to SLI board <br\> 16 IP station configured, not connected <br\> 17 IP station connected but not authorized <br\> 18 IP station connected and registered OK, auth not required <br\> 19 IP station connected and authorized <br\> 20 IP station connected but no license available <br\> | ||
| 6 | UINT2 | (*)Station RCI bitmap <br\>
1: RCI 1, 0 = off, 1 = on <br\> 2: RCI 2....<br\> | ||
| 7 | UINT2 | (*)Station RCO bitmap <br\>
1: RCO 1, 0 = off, 1 = on <br\> 2: RCO 2....<br\> | ||
| 8 | NET_OBJ_REF | (Empty REF in no conn active)Related station in connection. | ||
| 9 | UINT2 | (0 if no conn active)Connection reference as given in CONN_STATUS_BC | ||
| 10 | UINT1 | (0 if no conn active)CALL status as given in CALL_STATUS_BC | ||
| 11 | UINT4 | IP station hardware type. IP HW type ID : | ||
| 12 | UINT1 | Station type as defined in AlphaPro <br\>
Station type codes: | ||
| 13 | UINT4 | IPARIO status flags Bit number: 10 IPARIO down
| ||
| Response to: | GET_ST_STATE | |||
| (*) | Not implemented yet | |||
ST_STATE will be reported to the OPC server when:
- Mail queue changes from 0 to 1 or 1 to 0.
- Line state changes(Line fault etc)
- RCI changes on IP station.
- RCO changes on IP station.
Note: This command require an OPC Server license