Actions

Difference between revisions of "Anti-nuisance control (Event Handler)"

From Zenitel Wiki

Line 40: Line 40:
 
|-
 
|-
 
|}
 
|}
 
 
Event 1:
 
 
Event Owner: The guard station
 
Event type: 25 - Event trigger with parameter
 
Subevent: 0
 
When change to: ON
 
When Related To: All
 
Action:
 
$SSC L%2.dir U2
 
$ST L%2.dir W9000 L9999
 
 
Event 2:
 
 
Event Owner: Station w. UDP, Id: 8 (all stations)
 
Event type: 21 - Event timeout
 
Subevent: 0
 
When change to: ON
 
When Related To: Directory number  0 | 9999
 
Action:
 
 
  
  
 
[[Category:Applications]]
 
[[Category:Applications]]

Revision as of 22:50, 8 October 2007

A master station should be able to disable calls from substations for a periode of time.

In the programming example below the master station dials 9535 + substation number to disable calls from that station for 15 minutes.

Directory number 9535 is a two-step event trigger, feature 95/0. When dialled, an event type 25 is triggered and the action string $SSC L%2.dir U2 moves the station to COS 2. COS 2 is by default empty, which will prevent calls to be initiated. Also a 15 minute timer is started, $ST L%2.dir W9000 L9999. The timer will trigger event type 21 when timing out. Command $SSC L%2.dir U1 will then move the station back to COS 1.

Set transfer to dummy number 345 when not in Call Requester Mode:

Event Owner: The Master Station
Event type: 25 – Event trigger with parameter
Subevent: 0
When change to: ON
When related to: All
Action: $SSC L%2.dir U2
  $ST L%2.dir W9000 L9999

Reset transfer when in Call Requester Mode:

Event Owner: Stations w/UDP Id: 8 (All stations)
Event type: 21 – Event timer
When change to: ON
When related to: Directory number: 9999
Action: $SSC L%2.dir U1