== Station LED (on board and in front plate) == | == Station LED (on board and in front plate) == | ||
'''Blinking at 1 second interval''': Station does not have connection to the AlphaCom E exchange. | '''Blinking at 1 second interval''': Station does not have connection to the AlphaCom E exchange. <br> | ||
''Possible reasons'': | ''Possible reasons'': | ||
* No connection to Ethernet | * No connection to Ethernet | ||
| Line 8: | Line 8: | ||
* No or wrong gateway to the AlphaCom E exchange | * No or wrong gateway to the AlphaCom E exchange | ||
'''Blinking at 5 seconds interval''': Station has connection to the AlphaCom E exchange, but has not been registered. | '''Blinking at 5 seconds interval''': Station has connection to the AlphaCom E exchange, but has not been registered. <br> | ||
''Reason'': | ''Reason'': | ||
* Station has not been programmed in AlphaPro | * Station has not been programmed in AlphaPro | ||
'''No blinking''' | '''No blinking'''<br> | ||
''Possible reasons'': | ''Possible reasons'': | ||
* Station connected and registered to the AlphaCom E exchange - All OK | * Station connected and registered to the AlphaCom E exchange - All OK | ||
Revision as of 21:47, 10 October 2007
Station LED (on board and in front plate)
Blinking at 1 second interval: Station does not have connection to the AlphaCom E exchange.
Possible reasons:
- No connection to Ethernet
- Wrong AlphaCom E IP address configured
- Invalid IP address
- No or wrong gateway to the AlphaCom E exchange
Blinking at 5 seconds interval: Station has connection to the AlphaCom E exchange, but has not been registered.
Reason:
- Station has not been programmed in AlphaPro
No blinking
Possible reasons:
- Station connected and registered to the AlphaCom E exchange - All OK
- Station not powered up (if no other LEDs are active)
Status LED
- Blinking 2 red + 1 green: Station does not have connection to the AlphaCom E exchange
- Blinking 1 red + 2 green:Station has connection to AlphaCom E exchange, but has not been registered
- Blinking 3 green: Station connected and registered in the AlphaCom E exchange
LAN LEDs (on LAN and AUX RJ45-jacks)
Left green LED:
- Steady light: Ethernet connection OK
- Blinking: Ethernet traffic
- No light: No Ethernet connection
Right amber LED:
- Light: 100 Mbit Ethernet connection
- No light: 10 Mbit Ethernet connection