− | The [[status LED]] indicator is located in front of the cabinet ([[AlphaCom E20]] and [[AlphaCom E26]] only). The status LED is steady green when all is in order. | + | The [[status LED]] indicator is located in front of the cabinet ([[AlphaCom E20]] and [[AlphaCom E26]] only). The status LED is steady green when all is in order. An error situation is indicated by flashing red light: |
* System startup: Red -> Amber -> Green light | * System startup: Red -> Amber -> Green light | ||
* Board error: Red light. The AMC-IP board can no longer find one or more boards in the exchange (could be due to a faulty board, or a board has been removed). A board error in a MultiModule system is reported on the LED of the Master module, the LED in slave module will not indicate board error. | * Board error: Red light. The AMC-IP board can no longer find one or more boards in the exchange (could be due to a faulty board, or a board has been removed). A board error in a MultiModule system is reported on the LED of the Master module, the LED in slave module will not indicate board error. |
Revision as of 12:25, 3 January 2008
The status LED indicator is located in front of the cabinet (AlphaCom E20 and AlphaCom E26 only). The status LED is steady green when all is in order. An error situation is indicated by flashing red light:
- System startup: Red -> Amber -> Green light
- Board error: Red light. The AMC-IP board can no longer find one or more boards in the exchange (could be due to a faulty board, or a board has been removed). A board error in a MultiModule system is reported on the LED of the Master module, the LED in slave module will not indicate board error.
- MultiModule:
- Master module: Red light if the master module has lost contact with the slave(s)
- Slave module(s): If a slave has lost contact with the Master, the LED in the slave will light steady amber while the slave is rebooting, then the LED goes green when the module has come up in autonomy mode
- Remote Control Input (RCI): Red light when RCI is active. Requires software configuration from AlphaPro.