Actions

Difference between revisions of "Status LED"

From Zenitel Wiki

Line 6: Line 6:
 
**Master module: Red light if the master module has lost contact with the slave(s)
 
**Master module: Red light if the master module has lost contact with the slave(s)
 
**Slave module(s): If a slave has lost contact with the Master, the LED in the slave will light steady amber while the slave is rebooting, then the LED goes green when the module has come up in autonomy mode
 
**Slave module(s): If a slave has lost contact with the Master, the LED in the slave will light steady amber while the slave is rebooting, then the LED goes green when the module has come up in autonomy mode
* [[RCI|Remote Control Input]] (RCI): Red light when RCI is active. Requires software configuration from [[AlphaPro]].
+
* [[RCI|Remote Control Input]] (RCI): Red light when RCI is active. Requires software configuration from [[AlphaPro]]. In Exchange & System > RCI, set the flag "Activate Faulty Module LED".
  
  
 
The status LED can be reset by the [[Reset_Board_Error_Indication_feature|7871 code]].
 
The status LED can be reset by the [[Reset_Board_Error_Indication_feature|7871 code]].

Revision as of 13:13, 3 January 2008

The status LED indicator is located in front of the cabinet (AlphaCom E20 and AlphaCom E26 only). The status LED is steady green when all is in order. An error situation is indicated by flashing red light:

  • System startup: Red -> Amber -> Green light
  • Board error: Red light. The AMC-IP board can no longer find one or more boards in the exchange (could be due to a faulty board, or a board has been removed). A board error in a MultiModule system is reported on the LED of the Master module, the LED in slave module will not indicate board error.
  • MultiModule:
    • Master module: Red light if the master module has lost contact with the slave(s)
    • Slave module(s): If a slave has lost contact with the Master, the LED in the slave will light steady amber while the slave is rebooting, then the LED goes green when the module has come up in autonomy mode
  • Remote Control Input (RCI): Red light when RCI is active. Requires software configuration from AlphaPro. In Exchange & System > RCI, set the flag "Activate Faulty Module LED".


The status LED can be reset by the 7871 code.