Difference between revisions of "AlphaCom XE1"
From Zenitel Wiki
(→Serial Ports) |
(→Connections) |
||
Line 17: | Line 17: | ||
* There are two inputs for clean contacts on the [[RCI - Remote Contol Input|RCI connectors]] which can execute programmable functions. Note that the cabinet needs to be opened to get access to these connectors | * There are two inputs for clean contacts on the [[RCI - Remote Contol Input|RCI connectors]] which can execute programmable functions. Note that the cabinet needs to be opened to get access to these connectors | ||
* The serial ports with RS232 and RS422/RS485 interfaces are used for connecting to equipment using these protocols | * The serial ports with RS232 and RS422/RS485 interfaces are used for connecting to equipment using these protocols | ||
+ | |||
+ | [[File:XEsmallConnections.png|thumb|left|500px|XE1 IP and serial connections]] | ||
+ | <br style="clear:both;" /> | ||
====Serial Ports==== | ====Serial Ports==== |
Revision as of 15:22, 3 November 2016
Highlights
- Made to provide critical communication in any environment
- Supports 552 IP stations
- Environmental friendly and energy saving - max. 4 W
- SIM card based software configuration and disaster recovery
- Fully compatible with any AlphaCom system
Additional Documentation on Zenitel.com
Connections
- The exchange is normally powered from the mains via a 5 VDC power supply
- Two RJ-45 Ethernet terminals are used for IP LAN, WAN, Internet and AlphaNet IP communication. Eth0 is also used for programming
- There are two inputs for clean contacts on the RCI connectors which can execute programmable functions. Note that the cabinet needs to be opened to get access to these connectors
- The serial ports with RS232 and RS422/RS485 interfaces are used for connecting to equipment using these protocols
Serial Ports
Serial Port 0 - 9-Pin D-sub (RS232 Only)
- No additional settings necessary
Serial Port 1 - RJ45 (RS232/422/485)
- Additional settings:
- RS232:
- Switch 8 on S601 on the AMC-IP board must be set to OFF.
- RS422/485:
- Switch 8 on S601 on the AMC-IP board must be set to ON.
- Take off the top lid to reach the jumpers inside, and set them to the correct position.
- - RS485: Both jumpers in position 2-3 (default)
- - RS422: Both jumpers in position 1-2