Line 33: Line 33:
 
** Leave the other parameters as is. Press OK to close the window.
 
** Leave the other parameters as is. Press OK to close the window.
 
<br style="clear:both;" />
 
<br style="clear:both;" />
 +
[[Image:AlphaVision - Running.png|thumb|300px|AlphaVision screenshot - Communication OK and stations are detected and shown in the System Tree]]
 
* Start the AlphaVision program. Username = service, password = service (Supervisor login). The 'Message Window' at the bottom of the screen should show "Run Mode", and a green "eye" should appear at the bottom right corner, indicating the the communication between AlphaVision and AlphaCom is OK.
 
* Start the AlphaVision program. Username = service, password = service (Supervisor login). The 'Message Window' at the bottom of the screen should show "Run Mode", and a green "eye" should appear at the bottom right corner, indicating the the communication between AlphaVision and AlphaCom is OK.
[[Image:AlphaVision - Running.png|thumb|300px|left|AlphaVision screenshot - Communication OK and stations are detected and shown in the System Tree]]
+
* Select the 'System Tree' tab. AlphaVision will automatically detect stations as they are being used, and they will show up in the System Tree. However, by dialling the code [[Start Tone Test (Line Monitoring) feature|7885 (Tone Test)]] from a [[SuperUser]], all stations will automatically be detected one by one. (Initially only Station 102 will appear in the System Tree, as this is the default operator station. Double click on station 102 to open the tree to see all stations).
* Select the 'System tree' tab. AlphaVision will automatically detect stations as they are being used, and they will show up in the System Tree. However, by dialling the code [[Start Tone Test (Line Monitoring) feature|7885 (Tone Test)]] from a [[SuperUser]], all stations will automatically be detected one by one. (Initially only Station 102 will appear in the System Tree, as this is the default operator station. Double click on station 102 to open the tree to see all stations).
 
 
* Assign an 'Operator station' to AlphaVision by selecting Configuration -> Options -> Systems tab. By default station 102 in node 1 is set as operator station if found, and no other station is defined.
 
* Assign an 'Operator station' to AlphaVision by selecting Configuration -> Options -> Systems tab. By default station 102 in node 1 is set as operator station if found, and no other station is defined.

Revision as of 17:57, 26 November 2008

AlphaVision - Example configuration

This article gives step-by-step instructions how to get started with AlphaVision. Main configuration steps are:

  • AlphaWeb: Enable TCP port 55010
  • AlphaPro: Activate ACDP link and Device 64
  • AlphaVision: Configure communication parameters (AVCMSetup) and select 'Operator station'


AlphaWeb

  • In System Configuration -> Filters, enable TCP port 55010 on the ethernet port used for AlphaVision.

AlphaPro

  • In Exchange & System -> Serial ports, activate a communication port to be used for AlphaVision. Select one of the seven ACDP Links, and set the following parameters:
AlphaPro: Serial Ports setting
    • Port Type: TCP/IP Server
    • Link Type: Stentofon MultiDrop Master - Reserved
    • Broadcast: Enabled
    • Destination: AlphaVision (optional)
    • Port: 55010
    • Keep Alive: Enabled


AlphaPro: Device settings
    • Device type: Operator (passive)
    • Data (ACDP link): select the link which was configured in the Serial Ports window


AlphaVision

  • Download and install AlphaVision on a PC. Latest software version is available on the Zenitel download site.
  • Start the 'AVCMSetup' program (Windows XP: Start-> All Programs -> AlphaVision: AVCMSetup). Set:
AlphaVision: AVCMSetup
    • Communiation Type: IP
    • AC E IP address: The IP address of the AlphaCom
    • Leave the other parameters as is. Press OK to close the window.


AlphaVision screenshot - Communication OK and stations are detected and shown in the System Tree
  • Start the AlphaVision program. Username = service, password = service (Supervisor login). The 'Message Window' at the bottom of the screen should show "Run Mode", and a green "eye" should appear at the bottom right corner, indicating the the communication between AlphaVision and AlphaCom is OK.
  • Select the 'System Tree' tab. AlphaVision will automatically detect stations as they are being used, and they will show up in the System Tree. However, by dialling the code 7885 (Tone Test) from a SuperUser, all stations will automatically be detected one by one. (Initially only Station 102 will appear in the System Tree, as this is the default operator station. Double click on station 102 to open the tree to see all stations).