Actions

Difference between revisions of "Powering Additional Equipment"

From Zenitel Wiki

Line 2: Line 2:
  
 
==AlphaCom E7==
 
==AlphaCom E7==
 +
If the additional equipment is located in close proximity to an AlphaCom E7 Exchange, the exchange can provide 24VDC from a dedicated output. If other kind of power is required, or if the additional equipment is mounted away from the exchange, a suiteable local power supply is needed.
 
[[Image:E7 +24VDC Output.png|thumb|500px|left|E7: +24VDC Output]]
 
[[Image:E7 +24VDC Output.png|thumb|500px|left|E7: +24VDC Output]]
If the additional equipment is located in close proximity to an AlphaCom E7 Exchange, the exchange can provide 24VDC from a dedicated output. If other kind of power is required, or if the additional equipment is mounted away from the exchange, a suiteable local power supply is needed.
 
 
<br style="clear:both;" />
 
<br style="clear:both;" />
  
 
==AlphaCom E20==
 
==AlphaCom E20==
 +
The AlphaCom E20 Exchange has an ouput which allows for connection of +5VDC, +15VDC and +24VDC. Each output is protected by a 1 Ampere fuse. Additional equipment that requires an external power source may use these outputs.
 
[[Image:AlphaCom E20 power.png|thumb|500px|left|E20 Power outputs]]
 
[[Image:AlphaCom E20 power.png|thumb|500px|left|E20 Power outputs]]
The AlphaCom E20 Exchange has an ouput which allows for connection of +5VDC, +15VDC and +24VDC. Each output is protected by a 1 Ampere fuse. Additional equipment that requires an external power source may use these outputs.
 
 
<br style="clear:both;" />
 
<br style="clear:both;" />
  
 
==AlphaCom E26==
 
==AlphaCom E26==
[[Image:E26-PDB.png|thumb|500px|left|E26 with PDB board]]
 
 
When using additional equipment with an AlphaCom E26 Exchange, power can be distributed to the external equippment via the [[PDB - Power Distribution Board| Power Distribution Board, PDB]]. The PDB board provides +5VDC, +15VDC, +24VDC and +32VDC from a number of outputs with several different connection types.
 
When using additional equipment with an AlphaCom E26 Exchange, power can be distributed to the external equippment via the [[PDB - Power Distribution Board| Power Distribution Board, PDB]]. The PDB board provides +5VDC, +15VDC, +24VDC and +32VDC from a number of outputs with several different connection types.
 
The PDB board contains a 1 Ampere fuse for each voltage.
 
The PDB board contains a 1 Ampere fuse for each voltage.
 +
[[Image:E26-PDB.png|thumb|500px|left|E26 with PDB board]]
 +
<br style="clear:both;" />
  
  
 
[[Category:Hardware]]
 
[[Category:Hardware]]
 
[[Category:Additional equipment]]
 
[[Category:Additional equipment]]

Revision as of 10:34, 11 August 2014

Additional equipment often need power to be able to operate as intended. The source of such power varies depending on the type of exchange.

AlphaCom E7

If the additional equipment is located in close proximity to an AlphaCom E7 Exchange, the exchange can provide 24VDC from a dedicated output. If other kind of power is required, or if the additional equipment is mounted away from the exchange, a suiteable local power supply is needed.

E7: +24VDC Output


AlphaCom E20

The AlphaCom E20 Exchange has an ouput which allows for connection of +5VDC, +15VDC and +24VDC. Each output is protected by a 1 Ampere fuse. Additional equipment that requires an external power source may use these outputs.

E20 Power outputs


AlphaCom E26

When using additional equipment with an AlphaCom E26 Exchange, power can be distributed to the external equippment via the Power Distribution Board, PDB. The PDB board provides +5VDC, +15VDC, +24VDC and +32VDC from a number of outputs with several different connection types. The PDB board contains a 1 Ampere fuse for each voltage.

E26 with PDB board