Features
- Made for critical communication
- Vandal resistant
- Design in stainless steel (A304) to withstand corrosion
- Vandal resistant call button
- Superb audio quality (10 kHz)
- Advanced supervision functions
- External or extra call button option
- Can be placed up to 4km away from AlphaCom E exchange without local source power
Description
The STENTOFON Vandal Resistant Substation is tough, durable and resilient, and is designed for use in harsh environments. The station has a vandal proof design with 2mm stainless steel front, speaker/microphone protection and a stainless steel call button. The station provides high quality hands-free conversations, using the STENTOFON superb wideband audio and loud volume. Together with the durable design, this makes it the communication station of choice for prison cells, doors, gates and emergency points. The station can be placed up to 4 km from the AlphaCom exchange without need for any local power source. The station use the traditional 4-wire interface receiving both power and audio in the same cable. To provide maximum availability the station comes with advanced supervision functions. The station line test will detect if there is any faults in the network or station electronics. In addition the station support tone test, testing the complete transmission path including microphone and speaker. The status of the stations is reported to AlphaWeb as well as to 3rd party management systems using SNMP, Syslog or Microsoft OPC.
Specifications
Dimensions (H x W x D) | 180 x 92 x 25 mm |
Weight | 0.8 kg |
Protection | Vandal resistant design, 2 mm stainless steel front, Tamper proof fastening screws, button and loudspeaker grills |
Protection Class | IK 07, IP-44 |
Call Button | 22 mm diameter stainless steel |
Mounting | Flush mount in 50 mm deep back box, On-wall in 50 mm or 30 mm deep back box |
Operating Temp. | 0°C <-> +50°C |
Loudspeaker output | 1W RMS |
Requency range | 200 - 10'000 Hz |
Installation
Connectors | Line - 4 pin pluggable header External call button - 2 pin IDC |
Wiring | 2 twisted pairs |
Max cable distance | 4.0 km (18 AWG - 0.9 mm) 3.4 km (20 AWG - 0.8 mm) 2.0 km (22 AWG - 0.6 mm) 1.4 km (24 AWG - 0.5 mm) |
Power | Powered from exchange |
Call indication | Red call LED |
Supervision | Line supervision, Tone test (manual and automatic) Station status in AlphaWeb |