(Functional Changes/Enhancements)
(Functional Changes/Enhancements)
Line 13: Line 13:
 
*Config file name and format is changed with the new library. New config file name: '''Stentofon.AlphaCom.AlphaNet.OPC.xml'''<br/>The [[OPCServerConfigurator]] application will test for old config file, and prompt for automatic conversion to the new format.
 
*Config file name and format is changed with the new library. New config file name: '''Stentofon.AlphaCom.AlphaNet.OPC.xml'''<br/>The [[OPCServerConfigurator]] application will test for old config file, and prompt for automatic conversion to the new format.
 
*Implemented Redundant OPC Server mode allowing two OPC Devices connect to the same AlphaCom nodes. Requires AlphaCom Sys version 10.54
 
*Implemented Redundant OPC Server mode allowing two OPC Devices connect to the same AlphaCom nodes. Requires AlphaCom Sys version 10.54
 
+
<br\>
 
'''Easy Projects Activities'''
 
'''Easy Projects Activities'''
  
Line 36: Line 36:
 
| Redundant OPC Server
 
| Redundant OPC Server
 
|}
 
|}
 +
<br/>
 +
'''Limitations'''
 +
Global RCI/RCO states is updated on state changes, but is not synchronized at OPC Server startup.
  
 
== Errors Corrected ==
 
== Errors Corrected ==

Revision as of 11:38, 7 May 2009


Release State: Released
Release Version: 4.1.0.0


Upcomming 5.0.0.0

Functional Changes/Enhancements

Major changes

  • Re-written to use the new Stentofon.AlphaCom.AlphaNet.dll library.
  • Config file name and format is changed with the new library. New config file name: Stentofon.AlphaCom.AlphaNet.OPC.xml
    The OPCServerConfigurator application will test for old config file, and prompt for automatic conversion to the new format.
  • Implemented Redundant OPC Server mode allowing two OPC Devices connect to the same AlphaCom nodes. Requires AlphaCom Sys version 10.54

<br\> Easy Projects Activities

Activity Short Description
209 Make (IP) station IO items based on ST_STATE messages, make RCO/RCI item obsolete
210 Make global node RCI based on RCI_CHANGED messages incl OPC/RCI config
211 Implemented OPC Items for M-Key, C-Key and DAK-key
217 Updated to use library Stentofon.AlphaCom.AlphaNet.dll
166 Redundant OPC Server


Limitations Global RCI/RCO states is updated on state changes, but is not synchronized at OPC Server startup.

Errors Corrected

Easy Projects Activities

Activity Short Description
205 cr_iterate_command items offset
206 OPC AE: "Station UP" is reported on all ST_STATE changes

AlphaCom OPC Server 4.1.0.0 (2009-04-01)

Functional Changes/Enhancements

Added the OPC AE event StationSignal (.signal).
This event is generated from the station sending a Call Request ("I need attention")

AlphaCom OPC Server 4.0.0.0 (2008-10-29)

First official Release