Difference between revisions of "LOOP/ENDLOOP"
From Zenitel Wiki
m (→Useful example:) |
(→Useless example) |
||
Line 11: | Line 11: | ||
==Useless example== | ==Useless example== | ||
+ | Uses [[Tmp_statement|tmp]], [[%tmp]] and [[%op]] to control the loop | ||
tmp 0 "0" | tmp 0 "0" | ||
Line 21: | Line 22: | ||
ENDLOOP | ENDLOOP | ||
$put 8 "end loop %tmp(0) \n" | $put 8 "end loop %tmp(0) \n" | ||
+ | |||
The script prints the following text on [[TST]]: | The script prints the following text on [[TST]]: | ||
loop 0 | loop 0 |
Revision as of 07:19, 11 March 2010
The LOOP and ENDLOOP statements are used in the Event Handler. The LOOP - ENDLOOP statements can not be nested. When the script execution reaches ENDLOOP, the script jumps back to the previous LOOP statement.
IF/ENDIF along with STOP or BREAK must be used to exit from the loop.
As a safety precaution, looping will stop after 1000 iterations. Use LOOP with caution. Don't send more than a few dozen Data protocol messages from a single event.
This feature is new in AMC 11.00.
Examples
Useless example
Uses tmp, %tmp and %op to control the loop
tmp 0 "0" LOOP $put 8 "loop %tmp(0) \n" tmp 0 "%op(%tmp(0),+,1)" IF %op(%tmp(0),=,5) BREAK ENDIF ENDLOOP $put 8 "end loop %tmp(0) \n"
The script prints the following text on TST:
loop 0 loop 1 loop 2 loop 3 loop 4 end loop 5
Useful example:
This example switches off Audio Program on own station plus stations in Mutual exclusion group of own station, using TPROG and %ges.
$TPROG L%1.dir U%chg(0,1) tmp 0 "%ges(%1.phy, 0)" LOOP IF %op(%tmp(0),=,0) STOP ENDIF $TPROG N%tmp(0) U%chg(0,1) tmp 0 "%ges(%1.phy, %tmp(0))" ENDLOOP