− | [[File:1-3b config.PNG|left|thumb| | + | [[File:1-3b config.PNG|left|thumb|500px|System configuration]] |
<br style="clear:both;" /> | <br style="clear:both;" /> | ||
− | === | + | |
− | * | + | __NOTOC__ |
+ | |||
+ | === Station configuration === | ||
+ | ==== Configure the IP Substation ==== | ||
+ | * Perform a "Factory Default" setting on the IP Substation: | ||
+ | ** Press the call button | ||
+ | ** While the button is pressed, connect the IP Substation to the PoE switch | ||
+ | ** Wait until the call LED of the station has flashed two times | ||
+ | ** Release the call button and wait for two new flashes | ||
+ | ** Push the button briefly after the two flashes | ||
+ | * Assign the PC an IP address in the range 169.254.x.x | ||
+ | * Connect the PC to the network switch | ||
+ | [[File:1-3b solution1.PNG|thumb|left|280px|Accessing the IP Substations web page]] | ||
+ | <br style="clear:both;" /> | ||
+ | * On the PC start a web browser, and enter the IP station address 169.254.1.100 in the address field | ||
+ | * Log in with Username: '''admin''', password: '''alphaadmin''' | ||
+ | * Select '''Station Main''' -> '''Main Settings''', and enter the following parameters: | ||
+ | [[File:1-3b solution2.PNG|thumb|left|500px|Enter the IP settings in the IP Station web page]] | ||
+ | <br style="clear:both;" /> | ||
+ | * Connect the IP substation and the AlphaCom XE (Eth1) to the same network switch | ||
+ | |||
+ | ====Configure the AlphaCom XE==== | ||
+ | *In AlphaPro go to '''Users & Stations''', and select physical number 39; 139 Station 39 | ||
+ | *Use the section on the right and change the configuration as follows: | ||
+ | [[File:1-3b solution3.PNG|thumb|left|400px|AlphaPro: Users & Stations window]] | ||
+ | <br style="clear:both;" /> | ||
+ | |||
+ | === Call Button === | ||
+ | * In AlphaPro, '''Users & Stations''', select physical port 39. Then press the button '''DAK''', and configure as follows: | ||
+ | [[File:1-3b solution4.PNG|500px|thumb|left|AlphaPro: Users & Stations -> DAK window]] | ||
+ | <br style="clear:both;" /> | ||
+ | |||
+ | |||
+ | * Send the changes to the AlphaCom XE | ||
+ | [[File:SendChg.PNG|400px]] | ||
+ | <br><br> | ||
+ | |||
+ | === Troubleshooting === | ||
+ | * If the IP station does not register, check the following: | ||
+ | ** In AlphaWeb, System Configuration -> Filters, verify that port for '''IP Stations''' and '''VoIP Audio''' is enabled | ||
+ | ** In AlphaWeb, System Configuration -> Licenses, verify that there are licenses installed for the IP stations | ||
Line 11: | Line 51: | ||
===Related articles === | ===Related articles === | ||
* [[1-3b. IP Stations – Substations (practice)]] | * [[1-3b. IP Stations – Substations (practice)]] | ||
+ | |||
+ | [[Category: AlphaCom practice]] |
Latest revision as of 09:04, 30 June 2022
Station configuration
Configure the IP Substation
- Perform a "Factory Default" setting on the IP Substation:
- Press the call button
- While the button is pressed, connect the IP Substation to the PoE switch
- Wait until the call LED of the station has flashed two times
- Release the call button and wait for two new flashes
- Push the button briefly after the two flashes
- Assign the PC an IP address in the range 169.254.x.x
- Connect the PC to the network switch
- On the PC start a web browser, and enter the IP station address 169.254.1.100 in the address field
- Log in with Username: admin, password: alphaadmin
- Select Station Main -> Main Settings, and enter the following parameters:
- Connect the IP substation and the AlphaCom XE (Eth1) to the same network switch
Configure the AlphaCom XE
- In AlphaPro go to Users & Stations, and select physical number 39; 139 Station 39
- Use the section on the right and change the configuration as follows:
Call Button
- In AlphaPro, Users & Stations, select physical port 39. Then press the button DAK, and configure as follows:
- Send the changes to the AlphaCom XE
Troubleshooting
- If the IP station does not register, check the following:
- In AlphaWeb, System Configuration -> Filters, verify that port for IP Stations and VoIP Audio is enabled
- In AlphaWeb, System Configuration -> Licenses, verify that there are licenses installed for the IP stations