Actions

Difference between revisions of "TCIx Connections"

From Zenitel Wiki

m (Asle moved page TCIS Connections to TCIx Connections)
 
(27 intermediate revisions by 3 users not shown)
Line 1: Line 1:
[[File:TCIS Connections 1.PNG|right|400px]]
+
{{AEIPS}}
[[File:TCIS-X rear.PNG|left|350px]]
+
===Network Connection===
 +
Connect the Turbine Compact Station to the data network via the RJ45 plug. The unit supports Power over Ethernet (PoE 802.3af). It draws power from either the spare pairs or the signal line. If PoE is not available, the Turbine Compact Station can be powered from a 24 VDC local power supply.  
 +
[[File:TCIS-X top.PNG|thumb|left|250px|Turbine Compact top view]]
 
<br style="clear:both;" />
 
<br style="clear:both;" />
  
{| border="1"
+
=== External Connectors ===
|Ethernet/Power|| 10/100 Mbps Ethernet RJ-45 port for LAN (uplink) connection. Supports PoE (802.3af). Draws power from either spare line or signal line.
+
<!--[[File:TCIS Connections 1.PNG|right|250px|thumb|External Connectors on Turbine IP Station]]-->
|-
+
<gallery mode="traditional" widths=300px heights=300px perrow=2>
|Secondary Power || 24 VDC (16 – 48 V) secondary power is provided from an external adapter.
+
File:TCIS-X rear.PNG|TCIS and TCIV
|-
+
File:TCIV+ rear.png|TCIV+
|Relays || There is one Double Throw relay contact with 60W switching power. COM, NO, NC contacts are provided. Max: 250VAC/220VDC, 2A, 60W
+
</gallery>
|-
+
<br style="clear:both;" />
|Input/Output || 6 general purpose I/Os are available. Each I/O can be configured as either input, output, or LED driver.
 
|-
 
|Audio Line Out || A balanced 600 ohm audio line out with induction loop signal
 
|}
 
 
 
'''Note!''' Use cables crimped with ferrules for terminal block connectors
 
  
* When the Turbine Station is connected to the network, its IP address is automatically obtained from a DHCP server or an IP address in the range 169.254.x.x will be assigned.
+
*'''Ethernet/Power''': 10/100 Mbps Ethernet RJ-45 port for LAN (uplink) connection. Supports PoE (802.3af). Draws power from either spare line or signal line.
* To make the station speak its IP address, press the call button on the station.
+
*'''Secondary Power''': 24 VDC (16 – 48 V) secondary power is provided from an external adapter.
 
+
*'''Relays''': There is one Double Throw relay contact with 60W switching power. COM, NO, NC contacts are provided. Max: 250VAC/220VDC, 2A, 60W
===Power Supply===
+
*'''Input/Output''': 6 general purpose I/Os are available. Each I/O can be configured as either input, output, or LED driver.  
The Turbine Compact Station supports Power over Ethernet (PoE, IEEE 802.3 a-f) where power can be drawn from either the spare line or signal line. If PoE is not available, the Turbine Compact Station can be connected to a 24 VDC local power supply.
+
*'''Audio Line Out''': A balanced 600 ohm audio line out with induction loop signal
 
 
===Network Connection===
 
There is one RJ-45 port located on the Turbine Compact station that is used for PoE/LAN Ethernet connection.
 
  
 
===Input/Output Connections===
 
===Input/Output Connections===
 
There are 6 I/O connection options for the Turbine Compact Station.
 
There are 6 I/O connection options for the Turbine Compact Station.
These connections can be used to interface with external I/O devices. The connections are typically used as digital input (eg. from a closing contact), digital output (5V), or LED driving (20mA max) for connecting sensors, indicators or integration to other systems.
+
These connections are used as relay contacts for door lock control and external I/O devices.  
 +
 
 +
For more details see [[Turbine Compact Board Connectors]]
  
See also [[Turbine Compact Board Connectors]]
+
[[Category: Turbine Connections]]

Latest revision as of 14:13, 10 May 2023

AEIPS.png

Network Connection

Connect the Turbine Compact Station to the data network via the RJ45 plug. The unit supports Power over Ethernet (PoE 802.3af). It draws power from either the spare pairs or the signal line. If PoE is not available, the Turbine Compact Station can be powered from a 24 VDC local power supply.

Turbine Compact top view


External Connectors


  • Ethernet/Power: 10/100 Mbps Ethernet RJ-45 port for LAN (uplink) connection. Supports PoE (802.3af). Draws power from either spare line or signal line.
  • Secondary Power: 24 VDC (16 – 48 V) secondary power is provided from an external adapter.
  • Relays: There is one Double Throw relay contact with 60W switching power. COM, NO, NC contacts are provided. Max: 250VAC/220VDC, 2A, 60W
  • Input/Output: 6 general purpose I/Os are available. Each I/O can be configured as either input, output, or LED driver.
  • Audio Line Out: A balanced 600 ohm audio line out with induction loop signal

Input/Output Connections

There are 6 I/O connection options for the Turbine Compact Station. These connections are used as relay contacts for door lock control and external I/O devices.

For more details see Turbine Compact Board Connectors