Actions

Difference between revisions of "IP Desktop Station LED Indications"

From Zenitel Wiki

(Created page with "====Station LED==== LED4 - Red 5mm LED on board rear side, also seen through front plate. left|thumb|200px|Station LED <br style="clear:bo...")
 
 
(7 intermediate revisions by the same user not shown)
Line 1: Line 1:
 
====Station LED====
 
====Station LED====
 
LED4 - Red 5mm LED on board rear side, also seen through front plate.
 
LED4 - Red 5mm LED on board rear side, also seen through front plate.
[[File:IP Master Indications 1.PNG|left|thumb|200px|Station LED]]
+
[[File:IPDeskLED.png|left|thumb|200px|Station LED]]
 
<br style="clear:both;" />
 
<br style="clear:both;" />
<u>'''Blinking at 1 second intervals:'''</u>
+
'''Blinking at 1 second intervals:'''<br/>
 +
Station cannot register to the server/controller
  
*Station has no connection to the AlphaCom XE Audio Server.
+
Possible reasons:
 +
* Invalid network settings (IP address and network mask) in the device
 +
* Wrong or missing account settings (Server IP, directory number, password..)
 +
* Failing to register due to missing license in the server
 +
* The server is offline
 +
* Network or Server firewall is not blocking port 50001 (ICX-AlphaCom) or 5060 (Edge/SIP)
 +
If the server is on a different subnet, check that
 +
* A valid Default gateway is defined
  
Possible reasons:
+
'''No blinking:'''
:*No connection to Ethernet
 
:*Wrong AlphaCom IP address configured
 
:*Invalid IP address
 
:*No gateway or wrong gateway to the AlphaCom XE Audio Server
 
  
<u>'''Blinking at 5 second intervals:'''</u> <br/>
+
Possible reasons:  
*Station connected but NOT registered in the AlphaCom XE Audio Server.
+
* Station connected and registered to the ICX-AlphaCom
 +
* Station not powered up (if no other LEDs are active)
  
Reason:
 
:*Station has not been programmed in AlphaPro
 
:*Missing IP Station license in AlphaCom XE Audio Server
 
  
<u>'''No blinking:'''</u>
+
'''Blinking at 5 second intervals:'''<br/>
 +
{{Note| This LED behaviour only applies to INCA Desktop stations [[IP Desktop Master Station - 1008000000|1008000000]] and [[IP OR Master Station - 1008015000|1008015000]] in ICX-AlphaCom mode}}
 +
Station connected but NOT registered in the ICX-AlphaCom
  
 
Possible reasons:  
 
Possible reasons:  
:*Station connected and registered to the AlphaCom XE Audio Server
+
* Station has not been programmed in AlphaPro
:*Station not powered up (if no other LEDs are active)
+
* Missing IP Station license in the ICX-AlphaCom
 +
 
 +
[[Category:Station Indication LEDs]]

Latest revision as of 11:10, 20 November 2020

Station LED

LED4 - Red 5mm LED on board rear side, also seen through front plate.

Station LED


Blinking at 1 second intervals:
Station cannot register to the server/controller

Possible reasons:

  • Invalid network settings (IP address and network mask) in the device
  • Wrong or missing account settings (Server IP, directory number, password..)
  • Failing to register due to missing license in the server
  • The server is offline
  • Network or Server firewall is not blocking port 50001 (ICX-AlphaCom) or 5060 (Edge/SIP)

If the server is on a different subnet, check that

  • A valid Default gateway is defined

No blinking:

Possible reasons:

  • Station connected and registered to the ICX-AlphaCom
  • Station not powered up (if no other LEDs are active)


Blinking at 5 second intervals:

Note icon This LED behaviour only applies to INCA Desktop stations 1008000000 and 1008015000 in ICX-AlphaCom mode


Station connected but NOT registered in the ICX-AlphaCom

Possible reasons:

  • Station has not been programmed in AlphaPro
  • Missing IP Station license in the ICX-AlphaCom