====Station LED==== | ====Station LED==== | ||
LED4 - Red 5mm LED on board rear side, also seen through front plate. | LED4 - Red 5mm LED on board rear side, also seen through front plate. | ||
[[File: | [[File:IPDeskLED.png|left|thumb|200px|Station LED]] | ||
<br style="clear:both;" /> | <br style="clear:both;" /> | ||
'''Blinking at 1 second intervals:'''<br/> | |||
Station cannot register to the server/controller | |||
* | Possible reasons: | ||
* Invalid network settings (IP address and network mask) in the device | |||
* Wrong or missing account settings (Server IP, directory number, password..) | |||
* Failing to register due to missing license in the server | |||
* The server is offline | |||
* Network or Server firewall is not blocking port 50001 (ICX-AlphaCom) or 5060 (Edge/SIP) | |||
If the server is on a different subnet, check that | |||
* A valid Default gateway is defined | |||
'''No blinking:''' | |||
: | |||
Possible reasons: | |||
*Station connected | * Station connected and registered to the ICX-AlphaCom | ||
* Station not powered up (if no other LEDs are active) | |||
'''Blinking at 5 second intervals:'''<br/> | |||
{{Note| This LED behaviour only applies to INCA Desktop stations [[IP Desktop Master Station - 1008000000|1008000000]] and [[IP OR Master Station - 1008015000|1008015000]] in ICX-AlphaCom mode}} | |||
Station connected but NOT registered in the ICX-AlphaCom | |||
Possible reasons: | Possible reasons: | ||
* Station has not been programmed in AlphaPro | |||
* Missing IP Station license in the ICX-AlphaCom | |||
[[Category: | [[Category:Station Indication LEDs]] | ||
Latest revision as of 11:10, 20 November 2020
Station LED
LED4 - Red 5mm LED on board rear side, also seen through front plate.
Blinking at 1 second intervals:
Station cannot register to the server/controller
Possible reasons:
- Invalid network settings (IP address and network mask) in the device
- Wrong or missing account settings (Server IP, directory number, password..)
- Failing to register due to missing license in the server
- The server is offline
- Network or Server firewall is not blocking port 50001 (ICX-AlphaCom) or 5060 (Edge/SIP)
If the server is on a different subnet, check that
- A valid Default gateway is defined
No blinking:
Possible reasons:
- Station connected and registered to the ICX-AlphaCom
- Station not powered up (if no other LEDs are active)
Blinking at 5 second intervals:
| This LED behaviour only applies to INCA Desktop stations 1008000000 and 1008015000 in ICX-AlphaCom mode |
Station connected but NOT registered in the ICX-AlphaCom
Possible reasons:
- Station has not been programmed in AlphaPro
- Missing IP Station license in the ICX-AlphaCom