Difference between revisions of "AMG - Alarm Message to Group"
From Zenitel Wiki
(One intermediate revision by the same user not shown) | |||
Line 4: | Line 4: | ||
=== Syntax === | === Syntax === | ||
− | AMG | + | AMG <group.no> <alarm.no> |
*<group.no> = The index number of the group (1-250) | *<group.no> = The index number of the group (1-250) | ||
− | * | + | *<alarm.no> = The index number of the audio message (1-80) |
− | From software version 11.5.3.1: | + | From software version 11.5.3.1 it is possible to control if Handset and Volume Override should be used or not: |
− | AMG <group.no> | + | AMG <group.no> <alarm.no> <hvo> |
*<hvo> Optional parameter "handset volume override". 1 = on, 0 = off. Default = 1 | *<hvo> Optional parameter "handset volume override". 1 = on, 0 = off. Default = 1 | ||
Latest revision as of 08:47, 18 August 2023
AMG is used to play prerecorded audio message to a group of stations. The feature is using Volume Override, and will play the message at full volume.
Syntax
AMG <group.no> <alarm.no>
- <group.no> = The index number of the group (1-250)
- <alarm.no> = The index number of the audio message (1-80)
From software version 11.5.3.1 it is possible to control if Handset and Volume Override should be used or not:
AMG <group.no> <alarm.no> <hvo>
- <hvo> Optional parameter "handset volume override". 1 = on, 0 = off. Default = 1
Examples
AMG 4 3 – Alarm message 3 (8193) to group 4 (87) AMG 4 0 – Alarm message OFF to group 4 (87) AMG 4 3 0 – Alarm message 3 (8193) to group 4 (87), without volume override