Difference between revisions of "External Data Input"
From Zenitel Wiki
(→Example) |
(→Additional information) |
||
(5 intermediate revisions by 2 users not shown) | |||
Line 26: | Line 26: | ||
==Additional information== | ==Additional information== | ||
*Context parameters | *Context parameters | ||
− | :- [[ | + | :- [[edi (macro)|%edi]] is the input text where termination character is excluded |
:- [[%sev]] is the EDI port (sub-event) | :- [[%sev]] is the EDI port (sub-event) | ||
Line 32: | Line 32: | ||
:* [[%scutc]] - Extract substring by byte (character) position | :* [[%scutc]] - Extract substring by byte (character) position | ||
:* [[%scutf]] - Extract field, fields defined by delimiter character | :* [[%scutf]] - Extract field, fields defined by delimiter character | ||
+ | :* [[%strlen]] - Return length of string | ||
:* [[%sscan]] - Scan for string, extract rest of string after first match | :* [[%sscan]] - Scan for string, extract rest of string after first match | ||
:* [[%scmp]] - Compare strings | :* [[%scmp]] - Compare strings | ||
Line 40: | Line 41: | ||
== Example == | == Example == | ||
− | When receiving the | + | When receiving the text string "Start alarm 3", terminated by Line Feed character, play alarm message 3 (8193) to group 85: |
− | [[Image:EDI example.PNG|thumb|left| | + | [[Image:EDI example.PNG|thumb|left|1200px|Trigger event by text string from external device]] |
<br style="clear:both;" /> | <br style="clear:both;" /> | ||
Latest revision as of 09:39, 10 October 2023
The EDI ports are defined in AlphaPro: Exchange & System -> Serial Ports.
- The input message must have a termination character
- Maximum 128 characters. If longer strings, the first 128 characters will be returned, the rest will be ignored.
- Parsing the content is done in the action string in the Event Handler
Event description
Event Owner: | EDI Text Config |
Event type: | 28 - External Data Input |
Subevent: | 1 – 10: specifies which EDI port 0: matches all ports |
When change to ON: | When valid data is received on EDI port |
When change to OFF: | N/A |
When related to: | N/A |
Additional information
- Context parameters
- Useful macros and statements
- %scutc - Extract substring by byte (character) position
- %scutf - Extract field, fields defined by delimiter character
- %strlen - Return length of string
- %sscan - Scan for string, extract rest of string after first match
- %scmp - Compare strings
- TMP - Set temporary variable
- %tmp - Read temporary variable
The NUL character (ASCII 0x00) cannot be used in the EDI string. The processing of the string will be terminated when receiving NUL. |
Example
When receiving the text string "Start alarm 3", terminated by Line Feed character, play alarm message 3 (8193) to group 85: