Actions

AlphaPro 12 - Error messages: Difference between revisions

From Zenitel Wiki

(Created page with "If AlphaPro is not able to communictae with the AlphaCom server, there are several possible reasons: AlphaPro 12 error messages: * Wrong username/password for logging in (The...")
 
No edit summary
 
(15 intermediate revisions by one other user not shown)
Line 1: Line 1:
If AlphaPro is not able to communictae with the AlphaCom server, there are several possible reasons:
{{AI}}
If AlphaPro version 12 is not able to communicate with the AlphaCom server, there are several possible reasons:


AlphaPro 12 error messages:
AlphaPro 12 error messages:
* Wrong username/password for logging in (The remote server returned an error: (401) Unauthorized)
* ''The remote server returned an error: (401) Unauthorized'': Wrong [[Communicate (alphaPro)|username/password]] for logging in
* Incorrect IP address in AlphaPro (Exchange & System > System) - The IP address doesn't match the IP address of the AlphaCom (Unable to connect to the remote server)
* ''The remote server returned an error: (404) Not Found'': AlphaPro v.12 is used towards AlphaCom v. 11. See [[AlphaPro - Compatibility|compatibility chart]].
* AlphaPro v.12 is used towards AlphaCom v. 11. (The remote server returned an error: (404) Not Found)
* ''The remote server returned an error: [[(500) Internal Server Error|(500) Internal Server Error'']]: The AlphaCom has "Standby Stations" licenses installed (which is the case when the AlphaCom is used as a Secondary server in a [[Redundant Servers (AlphaCom XE)|redundant system]] with two AlphaCom servers)
* The AlphaCom has "Standby Stations" licenses installed (which is the case when the the AlphaCom is used as a standby server i et redundant system med to AlphaComer) (The remote server returned an error: (500) Internal Server Error)
* ''Unable to connect to x.x.x.x'' (x.x.x.x being the IP address): TCP port 60001 ("AlphaPro") is disabled in [[AlphaWeb#Filters|Filters setting]] in Web interface (Applies to SendAll/SendChg operations only)
* TCP port 60001 ("AlphaPro") is disabled in Filters setting in Web interface (SendAll/SendChg only) (Unable to connect to x.x.x.x)
* ''Unable to connect to the remote server'': Incorrect IP address in AlphaPro ([[Exchange_%26_System_(AlphaPro)#System|Exchange & System > System]]) - The IP address doesn't match the IP address of the AlphaCom
* TCP port 80 (HTTP) is disabled in Filters setting in Web interface (Unable to connect to the remote server)
* ''Unable to connect to the remote server'': TCP port 80 (HTTP) is disabled in [[AlphaWeb#Filters|Filters setting]] in Web interface
 
 
[[Category:AlphaPro Troubleshooting]]

Latest revision as of 09:53, 24 October 2023

AI.png

If AlphaPro version 12 is not able to communicate with the AlphaCom server, there are several possible reasons:

AlphaPro 12 error messages:

  • The remote server returned an error: (401) Unauthorized: Wrong username/password for logging in
  • The remote server returned an error: (404) Not Found: AlphaPro v.12 is used towards AlphaCom v. 11. See compatibility chart.
  • The remote server returned an error: (500) Internal Server Error: The AlphaCom has "Standby Stations" licenses installed (which is the case when the AlphaCom is used as a Secondary server in a redundant system with two AlphaCom servers)
  • Unable to connect to x.x.x.x (x.x.x.x being the IP address): TCP port 60001 ("AlphaPro") is disabled in Filters setting in Web interface (Applies to SendAll/SendChg operations only)
  • Unable to connect to the remote server: Incorrect IP address in AlphaPro (Exchange & System > System) - The IP address doesn't match the IP address of the AlphaCom
  • Unable to connect to the remote server: TCP port 80 (HTTP) is disabled in Filters setting in Web interface
MediaWiki spam blocked by CleanTalk.