+ | The SIP and RingMaster daemons ([[SIPD]],[[RMD]]) are communicating with [[AMCD]] through local IP sockets using the [[Stentofon Simple Link Layer]] protocol | ||
− | SIPD | + | SIPD connected to ACDP port 31 |
+ | RMD connected to ACDP port 32 | ||
− | * | + | *Every 5 second the daemon send an idle frame to [[AMCD]]. |
*If no idle frame is received from the daemon within 30 second the daemon is terminated by AMCD using: | *If no idle frame is received from the daemon within 30 second the daemon is terminated by AMCD using: | ||
− | + | '''/opt/amc/script/rmd stop''' | |
− | or | + | or |
− | + | '''/opt/amc/script/sipd stop''' | |
− | *5 seconds | + | |
− | + | *After 5 seconds the deamon is restarted by [[AMCD]] using: | |
− | or | + | '''/opt/amc/script/rmd start''' |
− | + | or | |
− | * If no idle frame is received from the daemon within 30 second the stop/start procedure is repeated, this will be | + | '''/opt/amc/script/sipd start''' |
+ | |||
+ | * If no new idle frame is received from the daemon within 30 second the stop/start procedure is repeated, this sequence will be repeated 5 times. | ||
+ | |||
+ | |||
+ | Example of [[Syslog (AlphaCom)|Syslog]] report for this sequence: | ||
+ | W(204.65) INFO_DP_LINK_DOWN, no:337 "" P1: 31, P2: 150, P3: 0 DP link down, port 31 node 150 device 0 | ||
+ | W(204.65) ERR_DAEMON, no:338 "SIPD start" P1: 31, P2: 0, P3: 1 | ||
+ | W(204.65) INFO_DP_IDLE_FRAME, no:339 "" P1: 31, P2: 150, P3: 0 Peer on ACDP port 31 is node 150 device 0 | ||
+ | |||
+ | [[Category: Protocols]] |
Latest revision as of 15:56, 6 July 2022
The SIP and RingMaster daemons (SIPD,RMD) are communicating with AMCD through local IP sockets using the Stentofon Simple Link Layer protocol
SIPD connected to ACDP port 31 RMD connected to ACDP port 32
- Every 5 second the daemon send an idle frame to AMCD.
- If no idle frame is received from the daemon within 30 second the daemon is terminated by AMCD using:
/opt/amc/script/rmd stop or /opt/amc/script/sipd stop
- After 5 seconds the deamon is restarted by AMCD using:
/opt/amc/script/rmd start or /opt/amc/script/sipd start
- If no new idle frame is received from the daemon within 30 second the stop/start procedure is repeated, this sequence will be repeated 5 times.
Example of Syslog report for this sequence:
W(204.65) INFO_DP_LINK_DOWN, no:337 "" P1: 31, P2: 150, P3: 0 DP link down, port 31 node 150 device 0 W(204.65) ERR_DAEMON, no:338 "SIPD start" P1: 31, P2: 0, P3: 1 W(204.65) INFO_DP_IDLE_FRAME, no:339 "" P1: 31, P2: 150, P3: 0 Peer on ACDP port 31 is node 150 device 0