Difference between revisions of "Group Call - Increased volume"
From Zenitel Wiki
(→Configuration) |
(→Configuration) |
||
(2 intermediate revisions by 2 users not shown) | |||
Line 25: | Line 25: | ||
tmp 0 "%gns(3, %tmp(0))" | tmp 0 "%gns(3, %tmp(0))" | ||
ENDLOOP | ENDLOOP | ||
− | + | STOP | |
ENDIF | ENDIF | ||
tmp 0 "%gns(3,0)" | tmp 0 "%gns(3,0)" | ||
Line 39: | Line 39: | ||
In the action strings above, there are two lines that defines the volume. Volume during group call is set to 6 (U6) by the command: | In the action strings above, there are two lines that defines the volume. Volume during group call is set to 6 (U6) by the command: | ||
− | + | {{Code|$VOL N%tmp(0) U6}} | |
Volume is set to 3 (U3) when the group call is ended by the command: | Volume is set to 3 (U3) when the group call is ended by the command: | ||
− | + | {{Code|$VOL N%tmp(0) U3}} | |
U6 and U3 can be changed to other values if required. | U6 and U3 can be changed to other values if required. | ||
Line 53: | Line 53: | ||
− | + | [[Category:AlphaCom Applications]] | |
− | [[Category: AlphaCom Applications]] | + | [[Category:ICX-AlphaCom Applications]] |
− | [[Category: ICX-AlphaCom Applications]] | + | [[Category:Applications using Event Handler]] |
Latest revision as of 14:22, 11 August 2022
This article describes how to increase the volume of a group call announcement. The volume is set back to default value when the group call is ended.
Prerequisites
- This event is CPU extensive. Maximum members in a group using this feature should not exceed approx. 50 stations. (Not applicable for ICX-AlphaCom)
- Minimum software: AMC version 11.
Configuration
In the following example the volume will be set to level 6 when group call 86 is called from stations in UDP group 2. The volume is set to level 3 (default) when the group call is ended.
When stations outside UDP group 2 dial group call 86 this event will not be triggered, and the volume will not be altered.
In AlphaPro, go to Exchange and System -> Events, press Insert and create the following event:
Action commands:
IF %chg(1,0) tmp 0 "%gns(3,0)" LOOP IF %op(%tmp(0),=,0) STOP ENDIF $VOL N%tmp(0) U6 tmp 0 "%gns(3, %tmp(0))" ENDLOOP STOP ENDIF tmp 0 "%gns(3,0)" LOOP IF %op(%tmp(0),=,0) STOP ENDIF $VOL N%tmp(0) U3 tmp 0 "%gns(3, %tmp(0))" ENDLOOP
In the action strings above, there are two lines that defines the volume. Volume during group call is set to 6 (U6) by the command:
$VOL N%tmp(0) U6
|
Volume is set to 3 (U3) when the group call is ended by the command:
$VOL N%tmp(0) U3
|
U6 and U3 can be changed to other values if required.
In %gns(3, %tmp(0)) in the example, the 3 stands for group 3 (86), and must be changed if a different group is used.
Note that a standard feature exists, which might be a better alternative: Group calls with "Setup Priority = Alarm" will automatically use the Volume Override feature of the ICX-AlphaCom, without any additional configuration required.