Latest revision as of 11:47, 30 June 2022

AI.png
DISCON_ST 0x008E 142 AMC 08.20
$DISCON_ST L101 2 Disconnect station 101 with success tone
Disconnect station from ongoing feature. Audio program is not affected.
1 NET_OBJ_REF
{ECL_STATION}
Station to disconnect
2 UINT1
(Optional)
Disconnect tone:
0: No tone (default)
1: Disconnection tone
2: success tone
3: failure tone
Response: COMMAND_RESPONSE is returned. Status = 0 if station already Idle, Status = 1 if some activity was disconnected. Parameter is physical number.
COMMAND_RESPONSE is returned after the disconnection tone (if any).