Actions

Difference between revisions of "VSF-Fortitude6 8.2 Release Notes"

From Zenitel Wiki

(Fixed Issues)
 
(6 intermediate revisions by 3 users not shown)
Line 1: Line 1:
 
* Previous Release - [[VSF-Fortitude6 8.1 Release Notes]]
 
* Previous Release - [[VSF-Fortitude6 8.1 Release Notes]]
 +
* Next Release - [[VSF-Fortitude6 9.0 Release Notes]]
  
 
This document provides the release notes for VSF-Fortitude6 8.2 with incremental bug fix releases. The release notes for VSF-Fortitude6 8.2 describe new features, improvements and issues fixed after VSF-Fortitude6 8.1.3.2.
 
This document provides the release notes for VSF-Fortitude6 8.2 with incremental bug fix releases. The release notes for VSF-Fortitude6 8.2 describe new features, improvements and issues fixed after VSF-Fortitude6 8.1.3.2.
Line 5: Line 6:
 
==Release info==
 
==Release info==
 
'''Name:''' VSF-Fortitude6 <br>
 
'''Name:''' VSF-Fortitude6 <br>
'''Description:''' VSF-Fortitude6 is a firmware for [[IP Desk Master -V2]], [[IP Desk Master -V2-P]], [[IP Flush Master -V2]] and [[IP-CROR]].
+
'''Description:''' VSF-Fortitude6 is a firmware for [[Zenitel Devices based on iMX6|Zenitel devices based on the IMX6 processor]].
  
 
The firmware is delivered in two different files:
 
The firmware is delivered in two different files:
Line 12: Line 13:
 
*vsff6-prod-8.2.3.x - Used in production- and recovery upgrades.
 
*vsff6-prod-8.2.3.x - Used in production- and recovery upgrades.
  
'''Version:''' 8.2.3.0<br>
+
'''Version:''' 8.2.3.3<br>
'''Date:''' 24.05.2024 <br>
+
'''Date:''' 22.07.2024 <br>
 
'''Status:''' General Availability<br>
 
'''Status:''' General Availability<br>
 +
 +
<br>
 +
 +
=VSF-FORTITUDE6 8.2.3.3=
 +
==Fixed Issues==
 +
===MTN-4525 ICX-Alphacom function Mask Volume Override did not work correctly===
 +
When event Mask Volume Override is sent to the device in “volume and handset” override, the loudspeaker will be muted when the handset is lifted, and it is possible to do a normal call while the alarm broadcast is received on the station. Depending on broadcast type, priority and setup, the alarm audio may be mixed with conversation audio.
 +
 +
===MTN-4505 Increased general cybersecurity for devices===
 +
 +
<br>
 +
 +
=VSF-FORTITUDE6 8.2.3.2=
 +
==Fixed Issues==
 +
=== MTN-4479 The relay output in the CRM-V2 was not working in ICX-AlphaCom Mode in version 8.2.3.0 and 8.2.3.1 ===
 +
This is now fixed.
 +
 +
=== MTN-4471 The IP telephony feature in IC-Edge was not working in version 8.2.3.0 and 8.2.3.1 ===
 +
This is now fixed.
  
 
<br>
 
<br>
Line 59: Line 79:
 
<br>
 
<br>
  
==Known Issues==
 
===MTN-4434 Downgrading to 8.1 or 8.0 SW version after factory reset brings the amplifier into reboot loop===
 
Downgrading amplifiers from the 8.2 SW version to the 8.1 or 8.0 SW version after factory resetting them brings them into a reboot loop. Downgrading the amplifier to a 7.5 SW version will work.
 
 
===MTN-4049 IP Heavy Duty Telephone shows speaker volume setting when in Edge Controller mode===
 
IP Heavy Duty Telephones do not have a speaker, this has been disabled in the device model. The setting option in Edge Controller mode does not do anything and should be ignored
 
 
===MTN-3489 Downgrading IP_LCM from vsft-6.4.3.0 will cause a reboot loop===
 
If downgrading the IP_LCM from vsft-6.4.3.0 to an earlier version, the IP_LCM will go into a reboot loop. Workaround is to factory reset the IP_LCM just after downgrading.
 
 
===MTN-3299 TLS Private Keys not restored on Turbine stations===
 
In case that TLS Private Keys are deleted from Turbine station, the only way to restore them is to manually upload them to the station. Factory reset or station upgrade will not restore TLS Private Keys.
 
 
===MTN-2692 Turbine stations won't register to ICX500 or AlphaCom if the dash symbol is not removed from the Directory Number field.===
 
In an unconfigured Turbine station there is a dash character in the Directory Number field in the "Main Settings menu. This dash symbol must be removed when the directory number is entered, else the station will fail to register.
 
 
===MTN-2686 Outputs not working for Exigo amplifiers in SIP mode===
 
GPO's does not work when exigo amplifiers are in SIP mode.
 
 
===MTN-2363 Factory reset does not delete uploaded Script===
 
All uploaded scripts should also be removed on Factory reset
 
 
===MTN-2362 H.264 RTSP stream in UDP mode can display small artifacts at the bottom of the stream===
 
H.264 RTSP stream in UDP mode can display small artifacts at the bottom of the stream.
 
 
===MTN-2361 TCIV H264 stream does not work in Honeywell Maxpro NVR===
 
RTSP H.264 does not work in Honeywell Maxpro NVR, workaround is to use MJPEG RTSP stream
 
 
===MTN-2360 Client side forwarding does not work in SIP mode===
 
Client side forwarding, which can be configured as a DAK action or activated from INCA display menu, does not work in SIP mode. Workaround is to use SIP server side forwarding.
 
 
===MTN-2359 Stream is not always established in Pelco VideoExpert VMS version 3.0 or newer===
 
Stream is not always established in Pelco VideoExpert VMS version 3.0 or newer, workaround is to follow all the steps described here https://wiki.zenitel.com/wiki/Adding_TCIV_ONVIF_camera_to_Pelco_VideoXpert_Professional when adding TCIV station to Pelco VideoExpert
 
 
===MTN-2358 Making a point-to-point call during High priority Group call will drop group call audio.===
 
When 2 stations establish a point-to-point call during High priority Group call, they will no longer receive audio from current High priority group call.
 
 
===MTN-2356 SNMP not working properly on TCIV under high CPU load===
 
SNMP is not working properly on TCIV under high CPU load, which means that SNMP traps and inform messages can be sent with delay, or not be sent at all. This only happens if TCIV is placed under very high load, under normal operating conditions SNMP function without any issues.
 
 
===MTN-2339 Group call chime is not played on 3rd party SIP stations===
 
Group call chime (WAV file) is not played on third party SIP devices when Group Call is set over multicast IP address.
 
 
===MTN-2220 Default SNMP settings issue with firmware downgrade to 4.9===
 
When downgrading from VSFT 4.11+ to 4.9 a factory reset is necessary if user wants to use default SNMP configuration. For custom snmp.conf file, re-upload with a custom snmp.conf file will fix the problem.
 
 
===MTN-1073 Group call fails if system previously configured with ZAP===
 
If system was configured with ZAP (VS-IMT Pulse SDK project) and then switched to XML configuration by deleting data.lua file, it is possible that Group Calls shall not work. A workaround is that (1) data.lua file is deleted from all stations including Pulse server - this will reboot stations, and (2) after reboot go to Server configuration -> Save + Apply - this will again reboot all stations.
 
  
  
  
 
[[Category: Release notes]]
 
[[Category: Release notes]]

Latest revision as of 12:32, 3 October 2024

This document provides the release notes for VSF-Fortitude6 8.2 with incremental bug fix releases. The release notes for VSF-Fortitude6 8.2 describe new features, improvements and issues fixed after VSF-Fortitude6 8.1.3.2.

Release info

Name: VSF-Fortitude6
Description: VSF-Fortitude6 is a firmware for Zenitel devices based on the IMX6 processor.

The firmware is delivered in two different files:

  • vsff6-8.2.3.x - Used for standard in-field upgrades
  • vsff6-prod-8.2.3.x - Used in production- and recovery upgrades.

Version: 8.2.3.3
Date: 22.07.2024
Status: General Availability


VSF-FORTITUDE6 8.2.3.3

Fixed Issues

MTN-4525 ICX-Alphacom function Mask Volume Override did not work correctly

When event Mask Volume Override is sent to the device in “volume and handset” override, the loudspeaker will be muted when the handset is lifted, and it is possible to do a normal call while the alarm broadcast is received on the station. Depending on broadcast type, priority and setup, the alarm audio may be mixed with conversation audio.

MTN-4505 Increased general cybersecurity for devices


VSF-FORTITUDE6 8.2.3.2

Fixed Issues

MTN-4479 The relay output in the CRM-V2 was not working in ICX-AlphaCom Mode in version 8.2.3.0 and 8.2.3.1

This is now fixed.

MTN-4471 The IP telephony feature in IC-Edge was not working in version 8.2.3.0 and 8.2.3.1

This is now fixed.


VSF-FORTITUDE6 8.2.3.0

Improvements

DS-899 SIP/SDP support for dynamic payload for codec L16x48 (HD-Audio)

Now supporting SIP media attribute L16/48000 with dynamic payload type in range 96..127. Note! The device needs to be configured in “HD-Audio” mode and voice processing (AEC and NC) is not supported.


Fixed Issues

MTN-4435 RTSP stream could stop in some cases

In case of audio issues, RTSP stream would terminate. Now the stream will continue with a moment of silence instead.

MTN-4394 Multicast paging working again on intercom devices

Multicast paging was not working on intercom devices when configuring from the webpage. This is now fixed.

MTN-4362 Fixed wrong description in Sound Detection settings

The description of “Minimum time before reactivation” is corrected to “Choose how long to wait before enabling VAD after triggering the DAK key”

MTN-4340 ONVIF backchannel could cut last second of audio

In some cases backchannel could cut around last second of audio when using push to talk or pre-recorded messages that terminate backchannel session.

This does not happen anymore if client sends TEARDOWN command correctly.

MTN-4329 Fixed an issue with wrong intervals for ONVIF events reports

Fixed an issue with wrong parsing of some PullMessages parameters. In some VMSs, PullMessages parameters Timeout and MessageLimit were not parsed correctly on VS-IS8.0.3.2 and wrong values were used.

MTN-4320 Weak cipher suites no longer supported on devices

Removed the AES128-SHA AES128-SHA256:ECDHE-RSA-AES128-SHA:ECDHE-RSA-AES256-SHA:CAMELLIA128-SHA:CAMELLIA256-SHA ciphers reported by security scanner

MTN-4246 Fixed an issue with input status on CRM-V2 that was lost after ICX-AlphaCom restart

After ICX-AlphaCom was restarted the input status of the CRM-V2 was lost. This is now fixed.

MTN-4228 Turbine devices could not be used with Bosch VMS

There was a problem on Zenitel ONVIF devices that caused software to crash and device to reboot which made Bosch VMS unable to connect to the device.