By default the [[Alarm message|ASVP alarm messages]] are repeated endlessly, but for some applications it is required that the message is played once or a few times and then stop. For each alarm message there is a parameter that controls the number of repetitions. As this parameter is not available from [[AlphaPro]], it has to be changed directly in the AMC memory, using the nvram editor in the [[TST console]] or the [[SNV|$SNV command]] from the [[Event Handler]]. | By default the [[Alarm message|ASVP alarm messages]] are repeated endlessly, but for some applications it is required that the message is played once or a few times and then stop. For each alarm message there is a parameter that controls the number of repetitions. As this parameter is not available from [[AlphaPro]], it has to be changed directly in the AMC memory, using the nvram editor in the [[TST console]] or the [[SNV|$SNV command]] from the [[Event Handler]]. | ||
Line 7: | Line 7: | ||
* From the [[TST_console#NVRAM_editor|nvram editor]] in the TST-console, go to: | * From the [[TST_console#NVRAM_editor|nvram editor]] in the TST-console, go to: | ||
− | + | {{code|.ex_mi.announce_tab[n].repeat}} | |
where n = message number. | where n = message number. | ||
Set number of repetitions of the alarm message (1 to 255, 255 is endless) | Set number of repetitions of the alarm message (1 to 255, 255 is endless) | ||
− | |||
=== Example === | === Example === | ||
Line 59: | Line 58: | ||
− | [[Category: | + | [[Category:ASVP]] |
Latest revision as of 15:09, 20 July 2022
By default the ASVP alarm messages are repeated endlessly, but for some applications it is required that the message is played once or a few times and then stop. For each alarm message there is a parameter that controls the number of repetitions. As this parameter is not available from AlphaPro, it has to be changed directly in the AMC memory, using the nvram editor in the TST console or the $SNV command from the Event Handler.
NOTE: Before continuing it is highly recommended to do a backup of AMC memory to Flash. Dial 7820+M from a SuperUser station.
Procedure
- From the nvram editor in the TST-console, go to:
.ex_mi.announce_tab[n].repeat
|
where n = message number.
Set number of repetitions of the alarm message (1 to 255, 255 is endless)
Example
Using the TST Console
Changing the parameter for alarm message 1 (Directory number 8191) to play once, then stop.
Start the TST Console, then:
Type: | Explanation |
---|---|
nvram <Enter><Enter> | Start the nvram editor from the TST console |
2 <Enter> | Enter line 2: .ex_mi… |
2 <Enter> | Enter line 2: .ex_mi_announce_tab[81] |
1 <Enter> | Select alarm message number 1 (*) |
3 <Enter> | Enter line 3: ….tab[1].repeat = 255 |
1 <Enter> | Set number of repetitions of alarm message, here 1 |
Q <Enter> | Exit NVRAM table, and save changes |
(*) Use message number 2 - 9 for the messages 8192 - 8199.
Using the Event Handler
Changing the parameter for alarm message 1 (Directory number 8191) to play once, then stop:
The event type 27, subvent 65, is triggered every time the exchange starts up.
Explanation of the parameters in the command $SNV Q1 W2 W2 W1 W3:
- Q1 = Number of repetitions, here 1
- W2 = NVRAM table 2, ex_mi…
- W2 = NVRAM subtable 2,.ex_mi_announce_tab[81]
- W1 = Message number 1 (*)
- W3 = NVRAM line 3, line 3: ….tab[1].repeat