Upgrade AlphaCom XE1 to ICX-510: Difference between revisions
From Zenitel Wiki
| (13 intermediate revisions by the same user not shown) | |||
| Line 3: | Line 3: | ||
[[File:UpgradeXE1toICX.png]] | [[File:UpgradeXE1toICX.png]] | ||
== Prerequisites== | |||
* Make sure you have licenses for the ICX-510. | |||
==AlphaCom XE1== | ==AlphaCom XE1== | ||
* Check AlphaCom XE1 software version. If the version is | * Check the AlphaCom XE1 software version. If the version is 11.x.x.x or older, the server should be upgraded to latest version, see [[AMC-IP software upgrade (Black AMC-IP board)|upgrade procedure]]. | ||
* Make screenshots of AlphaWeb System Configuration pages: | * Make screenshots of AlphaWeb System Configuration pages: | ||
# Interfaces | # Interfaces | ||
| Line 15: | Line 19: | ||
# Logging | # Logging | ||
# Messaging | # Messaging | ||
{{Note|If there are audio messages | {{Note|If there are [[ICX_Web#Messaging|pre-recorded audio messages]] on the server, download and store these on your laptop.}} | ||
* Use latest AlphaPro version and perform a Get All to backup the configuration. | * Use latest AlphaPro version and perform a '''Get All''' to backup the configuration. | ||
==ICX-AlphaCom == | ==ICX-AlphaCom == | ||
* Upgrade the ICX- | * Upgrade the ICX-510 to the latest software version | ||
* Log in to the [[ICX_Web|ICX-510 web-interface]] and configure according to the screenshots made of the AlphaCom XE1 | * Log in to the [[ICX_Web|ICX-510 web-interface]] and configure according to the screenshots made of the AlphaCom XE1 | ||
* [[ICX_Web#Messaging|Upload audio messages]] if any | * [[ICX_Web#Messaging|Upload audio messages]] if any | ||
* Upload license file | * Upload license file | ||
* | * Start AlphaPro and select the database you downloaded from the AlphaCom XE1. In '''Exchange & System''' > '''System''', set "Node Type" = '''ICX'''. | ||
* From AlphaPro restore the configuration by doing a '''Send All''', then '''Reset''' | |||
[[Category:AlphaCom Hardware]] | [[Category:AlphaCom Hardware]] | ||
Latest revision as of 14:06, 3 April 2025
This article describes best practice to replace an AlphaCom XE1 with an ICX-510 running AlphaCom software.
Prerequisites
- Make sure you have licenses for the ICX-510.
AlphaCom XE1
- Check the AlphaCom XE1 software version. If the version is 11.x.x.x or older, the server should be upgraded to latest version, see upgrade procedure.
- Make screenshots of AlphaWeb System Configuration pages:
- Interfaces
- Filters
- Routing
Optional:
- Time and Date
- Logging
- Messaging
| If there are pre-recorded audio messages on the server, download and store these on your laptop. |
- Use latest AlphaPro version and perform a Get All to backup the configuration.
ICX-AlphaCom
- Upgrade the ICX-510 to the latest software version
- Log in to the ICX-510 web-interface and configure according to the screenshots made of the AlphaCom XE1
- Upload audio messages if any
- Upload license file
- Start AlphaPro and select the database you downloaded from the AlphaCom XE1. In Exchange & System > System, set "Node Type" = ICX.
- From AlphaPro restore the configuration by doing a Send All, then Reset