Actions

Difference between revisions of "INCA Station Kit Restore Factory Defaults"

From Zenitel Wiki

m (1 revision imported)
 
(One intermediate revision by the same user not shown)
Line 3: Line 3:
 
* IP Substation Kit - [[IP Substation Kit - 1008090200|1008090200]]
 
* IP Substation Kit - [[IP Substation Kit - 1008090200|1008090200]]
 
* IP Master Station Kit [[IP Master Station Kit - 1008093000|100809300]]
 
* IP Master Station Kit [[IP Master Station Kit - 1008093000|100809300]]
 +
 +
<div style="text-align:left;"> <youtube width="300" height="180">WP9m-DG0hMU</youtube>  </div>
 +
  
 
The unit can be set to use either '''Static IP''' or '''DHCP'''. On the rear side of the PCB there is a red status LED. Pay attention to this LED during the restore procedure:
 
The unit can be set to use either '''Static IP''' or '''DHCP'''. On the rear side of the PCB there is a red status LED. Pay attention to this LED during the restore procedure:
Line 8: Line 11:
 
[[File:Load Defaults without KEY.PNG|right|thumb|800px|Connect a push button between pins 1 and 4]]
 
[[File:Load Defaults without KEY.PNG|right|thumb|800px|Connect a push button between pins 1 and 4]]
  
 +
== Procedure ==
 
# Connect a push button ('''KEY1''') between pin 1 and 4 on the P4 connector.
 
# Connect a push button ('''KEY1''') between pin 1 and 4 on the P4 connector.
 
# While pressing the button, power up the station kit and keep the button pressed.
 
# While pressing the button, power up the station kit and keep the button pressed.
Line 16: Line 20:
  
  
 
+
== Factory default values ==
Factory default values:
 
 
*Station Mode: '''Pulse'''
 
*Station Mode: '''Pulse'''
 
*Station IP address: '''169.254.1.100''' or '''DHCP'''
 
*Station IP address: '''169.254.1.100''' or '''DHCP'''

Latest revision as of 13:25, 15 May 2018

APS.png

This procedure is applicable for:


The unit can be set to use either Static IP or DHCP. On the rear side of the PCB there is a red status LED. Pay attention to this LED during the restore procedure:

Connect a push button between pins 1 and 4

Procedure

  1. Connect a push button (KEY1) between pin 1 and 4 on the P4 connector.
  2. While pressing the button, power up the station kit and keep the button pressed.
  3. Release the button after exactly 2 flashes of the LED.
  4. Let the LED flash for exactly 2 more times (Static IP) or exactly 4 more times (DHCP), then press the button again.
  5. Keep the button pressed until the LED flashes fast 2 times (Static IP) or flashes fast 4 times (DHCP) indicating a successful reset.
  6. Release the button and the station will restart with the factory default settings.


Factory default values

  • Station Mode: Pulse
  • Station IP address: 169.254.1.100 or DHCP
  • Username: admin
  • Password: alphaadmin