'''67 FEAT_ALARM_MSG'''
+
{{AI}}
{| border="1"
+
{|  
!style="background:#ffdead;"|Param1
 
!style="background:#ffdead;"|Description
 
 
|-
 
|-
| ?? || Start alarm message at station
+
|width="170pt"|'''Feature''':
 +
| Alarm Message to Station
 
|-
 
|-
|colspan="2"|Play alarm message on own station.
+
|'''Default directory number''': || 8190 - 8199
 +
|-
 +
|'''Feature number''': || 67
 +
|-valign="top"
 +
|'''Parameter 1''': || 1-9 = Alarm message number. 0 = Alarm Off
 +
|-valign="top"  
 +
|'''Description''': || Start playback of [[alarm message]] at own station by dialling the alarm number (8191 - 8199). The alarm message is switched off by dialling 8190. The feature requires [[ASVP]] board.
 +
<br>
 +
'''Additional information:'''
 +
*This feature is normally used together with the feature code 761 for [[Remote setup of Alarm message feature|Remote setup of Alarm message]].
 +
 
 +
*Alarm messages can also be triggered from the [[Event Handler]] or [[RCI]] by using the commands [[AMS - Alarm Message to Station|AMS]] or [[AMG]], or the [[ACDP|AlphaCom Data Protocol]] command [[ALARM MSG|$ALRM]]
  
Message is supplied from ASVP board.
+
'''See also:'''
+
* [[Add new ASVP alarm messages (MDF)]]
Message no 0 = OFF.
 
  
Message no range is 1-9.
 
|-
 
 
|}
 
|}
 +
  
  
 
[[AlphaCom Feature List|Back to feature list]]
 
[[AlphaCom Feature List|Back to feature list]]

Latest revision as of 09:53, 5 May 2023

AI.png
Feature: Alarm Message to Station
Default directory number: 8190 - 8199
Feature number: 67
Parameter 1: 1-9 = Alarm message number. 0 = Alarm Off
Description: Start playback of alarm message at own station by dialling the alarm number (8191 - 8199). The alarm message is switched off by dialling 8190. The feature requires ASVP board.


Additional information:

See also: