{| border="1" | {| border="1" | ||
|- | |- | ||
Line 37: | Line 37: | ||
0 Board not present | 0 Board not present | ||
− | 1 | + | 1 ASLT board present, no station |
− | 2 | + | 2 ASLT board present, station with failure |
− | 3 Station connected to | + | 3 Station connected to ASLT board |
16 IP station configured, not connected | 16 IP station configured, not connected | ||
− | 17 IP station connected but not authorized | + | 17 IP station connected but not authorized (currently not supported) |
18 IP station connected and registered OK, auth not required | 18 IP station connected and registered OK, auth not required | ||
− | 19 IP station connected and authorized | + | 19 IP station connected and authorized (currently not supported) |
− | 20 IP station connected but no license available | + | 20 IP station connected but no license available (currently not supported) |
|- | |- | ||
|align=center|6||[[UINT2]]||colspan="3"|Station RCI bitmap | |align=center|6||[[UINT2]]||colspan="3"|Station RCI bitmap | ||
Line 127: | Line 127: | ||
14 Fault led blinking. (Fault not acknowledged) <br> | 14 Fault led blinking. (Fault not acknowledged) <br> | ||
− | + | |- | |
− | + | |align=center|10||[[NET_OBJ_REF]](12.3.3.1)||colspan="3"|SX conference where the station is member. Invalid Net Ref if no active SX conference on station | |
|- | |- | ||
|colspan="2"|Response to:||colspan="3"|[[GET_ST_STATE]] | |colspan="2"|Response to:||colspan="3"|[[GET_ST_STATE]] |
Latest revision as of 12:08, 11 October 2021
ST_STATE | 0x009A | 154 | AMC 10.23 | |
---|---|---|---|---|
Response to the GET_ST_STATE message. | ||||
Current status of a station
Illegal station or no more stations available will return ST_STATE without parameters | ||||
1 | UINT2 | 1 -> 552: Station Physical Number | ||
2 | NET_OBJ_REF{ECL_STATION} | Default user Directory Number | ||
3 | TEXT16 | Default user Display text | ||
4 | UINT4 | State bitmap Bits:
1: 0 = Free, 1 = Busy 2: 0 = A station, 1 = B station in communication.(Param 8. describe related station) 3: 0 = M-rel, 1 = M-pres 4: 0 = Hook on, 1 = Hook off (*)5: 0 = privat off, 1 = private on 6: 0 = No mail, 1 = Mail in queue 7: 0 = Tone test OK, 1 = Failed. (11.1.3.2) | ||
5 | UINT1 | Line State
0 Board not present 1 ASLT board present, no station 2 ASLT board present, station with failure 3 Station connected to ASLT board 16 IP station configured, not connected 17 IP station connected but not authorized (currently not supported) 18 IP station connected and registered OK, auth not required 19 IP station connected and authorized (currently not supported) 20 IP station connected but no license available (currently not supported) | ||
6 | UINT2 | Station RCI bitmap
1: RCI 1, 0 = off, 1 = on 2: RCI 2.... | ||
7 | UINT2 | Station RCO bitmap
1: RCO 1, 0 = off, 1 = on 2: RCO 2.... | ||
8 | NET_OBJ_REF | (Empty REF in no conn active)Related station in connection. | ||
9 | UINT2 | (0 if no conn active)Connection reference as given in CONN_STATUS_BC | ||
10 | UINT1 | (0 if no conn active)CALL status as given in CALL_STATUS_BC | ||
11 | UINT4(11.2.3.7) | IP station hardware type. IP HW type ID : 32801 0x8021 SUB station board 1 32802 0x8022 SUB station board 2 32803 0x8023 Console board 32804 0x8024 IP Desktop 28708 0x7024 SoftClient 32806 0x8026 IP-ARIO 00256 0x0100 SIP Phone 00257 0x0101 IP Dummy station 00000 0x0000 Analog station/no station | ||
12 | UINT1(11.2.3.7) | Station type as defined in AlphaPro
Station type codes: 1 Sub Station 2 PNCI 3 CRM station 4 InterGuard 5 DualDisplay 6 Custom 7 SIP station 8 Conference Mixer | ||
13 | UINT4(11.2.3.7) | IPARIO status flags Bit number: 10 IPARIO down | ||
10 | NET_OBJ_REF(12.3.3.1) | SX conference where the station is member. Invalid Net Ref if no active SX conference on station | ||
Response to: | GET_ST_STATE | |||
(*) | Not implemented yet |
ST_STATE will be reported to the OPC server when:
- Mail queue changes from 0 to 1 or 1 to 0.
- Line state changes(Line fault etc)
- RCI changes on IP station.
- RCO changes on IP station.
Note: This command require an OPC Server license