Difference between revisions of "1-3b. IP Stations – Substations (solution)"
From Zenitel Wiki
Line 2: | Line 2: | ||
<br style="clear:both;" /> | <br style="clear:both;" /> | ||
=== Exercise === | === Exercise === | ||
− | |||
+ | __NOTOC__ | ||
+ | |||
+ | === Configure the IP Substation === | ||
+ | * Perform a "Factory Default" setting on the IP Substation | ||
+ | ** Press the call button | ||
+ | ** While the button is pressed, connect the IP Substation to the PoE switch | ||
+ | ** Wait until the call LED of the station starts to flash | ||
+ | ** Release the call button for exactly two flashes | ||
+ | ** Push the button briefly | ||
+ | * Assign the PC an IP address in the range 169.254.x.x | ||
+ | * Connect the PC to the network switch | ||
+ | |||
+ | * Step to the menu selection '''IP Settings''' and enter the following parameters (''IPgw'' is not relevant here): | ||
+ | [[File:1-3a solution1.png|thumb|left|250px|Off-line menu: IP settings]] | ||
+ | <br style="clear:both;" /> | ||
+ | * When prompted, '''Save''' the changes. When asked for "Restart now" you can select "No". | ||
+ | * Step to the menu selection '''AlphaCom IP''' and enter the following parameters: | ||
+ | [[File:1-3a solution2.png|thumb|left|250px|Off-line menu: AlphaCom settings]] | ||
+ | <br style="clear:both;" /> | ||
+ | * When prompted, '''Save''' the changes. | ||
+ | * Step to the menu selection '''Restart''' and activate a restart of the station | ||
+ | |||
+ | |||
+ | ===Configure the AlphaCom XE=== | ||
+ | *In AlphaPro go to '''Users & Stations''', and select physical number 37; 137 Station 37 | ||
+ | *Use the section on the right and change the configuration as follows: | ||
+ | [[File:1-3a solution5.png|thumb|left|400px|AlphaPro: Users & Stations window]] | ||
+ | <br style="clear:both;" /> | ||
+ | |||
+ | *In AlphaPro go to '''Users & Stations''', and select physical number 38; 138 Station 38 | ||
+ | *Use the section on the right and change the configuration as follows: | ||
+ | |||
+ | [[File:1-3a solution6.png|thumb|left|400px|AlphaPro: Users & Stations window]] | ||
+ | <br style="clear:both;" /> | ||
+ | |||
+ | * Send the changes to the AlphaCom XE | ||
+ | [[File:SendChg.PNG|400px]] | ||
<br><br><br><br> | <br><br><br><br> |
Revision as of 16:41, 22 March 2011
Exercise
Configure the IP Substation
- Perform a "Factory Default" setting on the IP Substation
- Press the call button
- While the button is pressed, connect the IP Substation to the PoE switch
- Wait until the call LED of the station starts to flash
- Release the call button for exactly two flashes
- Push the button briefly
- Assign the PC an IP address in the range 169.254.x.x
- Connect the PC to the network switch
- Step to the menu selection IP Settings and enter the following parameters (IPgw is not relevant here):
- When prompted, Save the changes. When asked for "Restart now" you can select "No".
- Step to the menu selection AlphaCom IP and enter the following parameters:
- When prompted, Save the changes.
- Step to the menu selection Restart and activate a restart of the station
Configure the AlphaCom XE
- In AlphaPro go to Users & Stations, and select physical number 37; 137 Station 37
- Use the section on the right and change the configuration as follows:
- In AlphaPro go to Users & Stations, and select physical number 38; 138 Station 38
- Use the section on the right and change the configuration as follows:
- Send the changes to the AlphaCom XE