+ | * On the PC start a web browser, and enter the IP station address 169.254.1.100 in the address field | ||
* When prompted, '''Save''' the changes. When asked for "Restart now" you can select "No". | * When prompted, '''Save''' the changes. When asked for "Restart now" you can select "No". | ||
* Step to the menu selection '''AlphaCom IP''' and enter the following parameters: | * Step to the menu selection '''AlphaCom IP''' and enter the following parameters: |
Revision as of 16:48, 22 March 2011
Configure the IP Substation
- Perform a "Factory Default" setting on the IP Substation
- Press the call button
- While the button is pressed, connect the IP Substation to the PoE switch
- Wait until the call LED of the station starts to flash
- Release the call button for exactly two flashes
- Push the button briefly
- Assign the PC an IP address in the range 169.254.x.x
- Connect the PC to the network switch
- On the PC start a web browser, and enter the IP station address 169.254.1.100 in the address field
- When prompted, Save the changes. When asked for "Restart now" you can select "No".
- Step to the menu selection AlphaCom IP and enter the following parameters:
- When prompted, Save the changes.
- Step to the menu selection Restart and activate a restart of the station
Configure the AlphaCom XE
- In AlphaPro go to Users & Stations, and select physical number 37; 137 Station 37
- Use the section on the right and change the configuration as follows:
- In AlphaPro go to Users & Stations, and select physical number 38; 138 Station 38
- Use the section on the right and change the configuration as follows:
- Send the changes to the AlphaCom XE