Actions

Difference between revisions of "INCA Station Kit Restore Factory Defaults"

From Zenitel Wiki

(Restore with Static IP)
(Restore with Activated DHCP)
Line 35: Line 35:
 
# Release the button and the station kit will restart with the factory default settings.
 
# Release the button and the station kit will restart with the factory default settings.
  
{| class="wikitable"
+
Factory default values:
!style="background:#ffdead" colspan="2"|Factory default values
+
*Station Mode: '''Pulse'''
|-
+
*Station IP address: '''From DHCP server'''
| Station Mode || align=center | '''Pulse'''
+
*Username: '''admin'''
|-
+
*Password: '''alphaadmin'''
| Station IP address || align=center | '''determined by DHCP server'''
 
|-
 
| AlphaCom IP address || align=center | '''169.254.1.5'''
 
|-
 
| Username* || align=center | '''admin'''
 
|-
 
| Password* || align=center | '''alphaadmin'''
 
|-
 
|}
 
  
 
  * Software 01.06 and earlier: '''ADMIN/alphacom''')
 
  * Software 01.06 and earlier: '''ADMIN/alphacom''')
  
 
[[Category: INCA - Restore Factory Defaults and Software Upgrade]]
 
[[Category: INCA - Restore Factory Defaults and Software Upgrade]]

Revision as of 13:02, 17 March 2017

This procedure is applicable for:


The Factory Default can be either set to Static IP 169.254.1.100 or activate DHCP.

Connect a push button (KEY1) between pin 1 and 4 on the P4 connector.

Load Defaults without KEY.PNG


Restore with Static IP

  1. While pressing the button, power up the station kit.
  2. When the station kit LED starts blinking, release the button after exactly 2 blinks.
  3. Let the LED blink for exactly 2 more times, then press the button again.
  4. Keep the button pressed until the LED blinks fast 2 times indicating a successful reset with static IP.
  5. Release the button and the station kit will restart with the factory default settings.

Factory default values:

  • Station Mode: Pulse
  • Station IP address: 169.254.1.100
  • Username: admin
  • Password: alphaadmin
* Software 01.06 and earlier: ADMIN/alphacom)

Restore with Activated DHCP

The DHCP option is available from software version 01.07.

  1. While pressing the button, power up the station kit.
  2. When the station kit LED starts blinking, release the button after exactly 2 blinks.
  3. Let the LED blink for exactly 4 more times, then press the button again.
  4. Keep the button pressed until the LED blinks fast 4 times indicating a successful reset with activated DHCP.
  5. Release the button and the station kit will restart with the factory default settings.

Factory default values:

  • Station Mode: Pulse
  • Station IP address: From DHCP server
  • Username: admin
  • Password: alphaadmin
* Software 01.06 and earlier: ADMIN/alphacom)