{{APS}}This procedure is applicable for:
 
 
* [[IP Heavy Duty Station|IP Heavy Duty station 1008072xx0]]
 
 
 
The Factory Default can be either set to Static IP 169.254.1.100 or activate DHCP.
 
 
Connect a push button ('''KEY1''') between pin 1 and 4 on the P4 connector.
 
 
[[File:Load Defaults without KEY.PNG|left]]
 
<br style="clear:both;" />
 
 
== Restore with Static IP ==
 
# While pressing the button, power up the station kit.
 
# When the station kit LED starts blinking, release the button '''after exactly 2 blinks'''.
 
# Let the LED blink for '''exactly 2 more times''', then press the button again.
 
# Keep the button pressed until the LED '''blinks fast 2 times''' indicating a successful reset with static IP.
 
# Release the button and the station kit will restart with the factory default settings.
 
 
Factory default values:
 
*Station Mode: '''Pulse'''
 
*Station IP address: '''169.254.1.100'''
 
*Username: '''admin'''
 
*Password: '''alphaadmin'''
 
 
== Restore with Activated DHCP ==
 
The DHCP option is available from software version 01.07.
 
# While pressing the button, power up the station kit.
 
# When the station kit LED starts blinking, release the button '''after exactly 2 blinks'''.
 
# Let the LED blink for '''exactly 4 more times''', then press the button again.
 
# Keep the button pressed until the LED '''blinks fast 4 times''' indicating a successful reset with activated DHCP.
 
# Release the button and the station kit will restart with the factory default settings.
 
 
Factory default values:
 
*Station Mode: '''Pulse'''
 
*Station IP address: '''From DHCP server'''
 
*Username: '''admin'''
 
*Password: '''alphaadmin'''
 
  
  
 
[[Category: INCA - Restore Factory Defaults and Software Upgrade]]
 
[[Category: INCA - Restore Factory Defaults and Software Upgrade]]

Revision as of 13:27, 17 March 2017

APS.png

This procedure is applicable for:

The unit can be set to use either Static IP or DHCP. On the rear side of the PCB there is a red status LED. Pay attention to this LED during the restore procedure:

Connect a push button between pins 1 and 4
  1. Connect a push button (KEY1) between pin 1 and 4 on the P4 connector.
  2. While pressing the button, power up the station kit and keep the button pressed.
  3. Release the button after exactly 2 flashes of the LED.
  4. Let the LED flash for exactly 2 more times (Static IP) or exactly 4 more times (DHCP), then press the button again.
  5. Keep the button pressed until the LED flashes fast 2 times (Static IP) or flashes fast 4 times (DHCP) indicating a successful reset.
  6. Release the button and the station will restart with the factory default settings.

Factory default values:

  • Station Mode: Pulse
  • Station IP address: 169.254.1.100 or DHCP
  • Username: admin
  • Password: alphaadmin