Difference between revisions of "INCA Station Restore Factory Defaults"
From Zenitel Wiki
Line 1: | Line 1: | ||
{{APS}} | {{APS}} | ||
− | |||
This procedure is applicable for the stations: | This procedure is applicable for the stations: | ||
* IP Substations - [[Weather and Vandal Resistant IP Substation - 1008041100|1008041100]]/[[Weather and Vandal Resistant IP Substation for 3 gang Back Box - 1008051000|1008051000]] | * IP Substations - [[Weather and Vandal Resistant IP Substation - 1008041100|1008041100]]/[[Weather and Vandal Resistant IP Substation for 3 gang Back Box - 1008051000|1008051000]] | ||
Line 6: | Line 5: | ||
* [[IP Master Station Kit - 1008093000]] - A push button must be connected between pin 1 and pin 4 on connector P4. | * [[IP Master Station Kit - 1008093000]] - A push button must be connected between pin 1 and pin 4 on connector P4. | ||
* The [[IP Substation Kit - 1008090200]] - A push button must be connected between pin 1 and pin 4 on connector P4. | * The [[IP Substation Kit - 1008090200]] - A push button must be connected between pin 1 and pin 4 on connector P4. | ||
+ | <div style="text-align:right;"> <youtube width="300" height="180">-RDBOLvI-lo</youtube> </div> | ||
[[File:Load Defaults without KEY.PNG|left|thumb|300px|Kits require a push button to be connected between pins 1 and 4]] | [[File:Load Defaults without KEY.PNG|left|thumb|300px|Kits require a push button to be connected between pins 1 and 4]] | ||
<br style="clear:both;" /> | <br style="clear:both;" /> | ||
+ | |||
'''Procedure:'''<br> | '''Procedure:'''<br> | ||
When loading factory defalt settings, the unit can be set to use either '''Static IP''' or '''DHCP'''. | When loading factory defalt settings, the unit can be set to use either '''Static IP''' or '''DHCP'''. | ||
Line 24: | Line 25: | ||
*Password: '''alphaadmin''' | *Password: '''alphaadmin''' | ||
− | |||
Revision as of 13:52, 3 May 2018
This procedure is applicable for the stations:
- IP Substations - 1008041100/1008051000
- IP Video Door Stations - 1401110100/1401110200
- IP Master Station Kit - 1008093000 - A push button must be connected between pin 1 and pin 4 on connector P4.
- The IP Substation Kit - 1008090200 - A push button must be connected between pin 1 and pin 4 on connector P4.
Procedure:
When loading factory defalt settings, the unit can be set to use either Static IP or DHCP.
- While pressing the call button, power up the station and keep the button pressed.
- Release the button after exactly 2 flashes of the LED.
- Let the LED flash for exactly 2 more times (Static IP) or exactly 4 more times (DHCP), then press the button again.
- Keep the button pressed until the LED flashes fast 2 times (Static IP) or flashes fast 4 times (DHCP) indicating a successful reset.
- Release the button and the station will restart with the factory default settings.
Factory default values:
- Station Mode: Pulse
- Station IP address: 169.254.1.100 (Static) or DHCP
- Username: admin
- Password: alphaadmin