Actions

Difference between revisions of "Flowire"

From Zenitel Wiki

Line 15: Line 15:
  
 
== Reset to Factory defaults ==
 
== Reset to Factory defaults ==
Flowire can be reset to Factory defaults by pressing the button for 15 seconds. The recessed button is located next to the Ethernet connector. (Handled by ''managerd'' process.)
+
Flowire can be reset to Factory defaults by pressing the button for 15 seconds. The recessed button is located next to the Ethernet connector.
  
 
[[Category: Flowire]]
 
[[Category: Flowire]]

Revision as of 12:39, 31 May 2018

APS.png
TCIS-1

Flowire is based on the HomePlug AV power line communications specification, only using 24 - 48 V DC as the medium. It is a network bridge between Ethernet and a PLC link.

There are two variants

  • FCDC-1 (1008080110 ) - Forwards power to the spare pairs of the Ethernet port
  • FCDC-2 (1008080210) - Does not forward power to the Ethernet port
Note icon FCDC-1 forwards the power from the Power Supply Unit. This is not true PoE (Power over Ethernet) technology


Factory defaults

  • Static IP address : 169.254.1.10
  • DHCP enabled. If obtain an dynamic address, it comes in addition to the static address.
  • NMK Password: HomePlugAV0123

MAC address range: 00:13:CB:0A:00:00 -> 00:13:CB:0A:80:00

Reset to Factory defaults

Flowire can be reset to Factory defaults by pressing the button for 15 seconds. The recessed button is located next to the Ethernet connector.