Difference between revisions of "Flowire"
From Zenitel Wiki
Line 6: | Line 6: | ||
* [[FCDC-1]] (1008080110 ) - Forwards power to the spare pairs of the Ethernet port | * [[FCDC-1]] (1008080110 ) - Forwards power to the spare pairs of the Ethernet port | ||
* [[FCDC-2]] (1008080210) - Does not forward power to the Ethernet port | * [[FCDC-2]] (1008080210) - Does not forward power to the Ethernet port | ||
− | {{note|FCDC-1 forwards the power from the Power Supply Unit to the Ethernet port. This is not true [[PoE]] (Power over Ethernet) technology }} | + | {{note|FCDC-1 forwards the power from the Power Supply Unit to the Ethernet port. This is '''not''' true [[PoE]] (Power over Ethernet) technology }} |
== Factory defaults == | == Factory defaults == | ||
* Static IP address : '''169.254.1.10''' | * Static IP address : '''169.254.1.10''' |
Revision as of 12:41, 31 May 2018
Flowire is based on the HomePlug AV power line communications specification, only using 24 - 48 V DC as the medium. It is a network bridge between Ethernet and a PLC link.
There are two variants:
- FCDC-1 (1008080110 ) - Forwards power to the spare pairs of the Ethernet port
- FCDC-2 (1008080210) - Does not forward power to the Ethernet port
FCDC-1 forwards the power from the Power Supply Unit to the Ethernet port. This is not true PoE (Power over Ethernet) technology |
Factory defaults
- Static IP address : 169.254.1.10
- DHCP enabled. If obtain an dynamic address, it comes in addition to the static address.
- NMK Password: HomePlugAV0123
MAC address range: 00:13:CB:0A:00:00 -> 00:13:CB:0A:80:00
Reset to Factory defaults
Flowire can be reset to Factory defaults by pressing the button for 15 seconds. The recessed button is located next to the Ethernet connector.