Line 10: Line 10:
  
 
Relay ratings:
 
Relay ratings:
* '''Outputs''': DPDT (NO, NC, COM)
+
* '''Outputs''': DPDT (Double Pole Double Throw). NO (Normal Open), NC (Normal Closed), COM (Common)
 
* '''Switched voltage''': < 250VAC Rated (400VAC Max)
 
* '''Switched voltage''': < 250VAC Rated (400VAC Max)
 
* '''Switched Voltage''': < 2000 VA max
 
* '''Switched Voltage''': < 2000 VA max

Revision as of 13:38, 10 January 2019

IPLCM.png

Inputs

From the top left the inputs are numbered as pin 17 to pin 24. Each input has a corresponding input switch which toggles between closing contact and active input.

Outputs

From the left side the outputs are numbered as pin 17 to pin 24. Each output is a dual pole relay with normally open, normally close and common available on the pin header.
The bottom four outputs each has a corresponding switch. This allows forwarding power from the power forwarding connector to the relay normally open and common on each output.


Relay ratings:

  • Outputs: DPDT (Double Pole Double Throw). NO (Normal Open), NC (Normal Closed), COM (Common)
  • Switched voltage: < 250VAC Rated (400VAC Max)
  • Switched Voltage: < 2000 VA max
  • Switching Current: < 8A rated (15A max, 4s)

Indicators

Each output has a LED which indicates if the output is active or not.


See here for for information on the TKIS-2 kit connections