Difference between revisions of "IP-LCM Connections"
From Zenitel Wiki
(→Inputs) |
|||
Line 3: | Line 3: | ||
== Inputs == | == Inputs == | ||
Each of the 8 inputs has a corresponding input switch, which selects between a dry closing contact os an active input. | Each of the 8 inputs has a corresponding input switch, which selects between a dry closing contact os an active input. | ||
− | * Left position: The input | + | * Left position: The input requires an active signal, typically 5, 12V or 24VDC. The input is galvanic isolated with an opto-coupler. |
+ | * Right position: The input requires a dry contact | ||
== Outputs == | == Outputs == |
Revision as of 14:34, 10 January 2019
Inputs
Each of the 8 inputs has a corresponding input switch, which selects between a dry closing contact os an active input.
- Left position: The input requires an active signal, typically 5, 12V or 24VDC. The input is galvanic isolated with an opto-coupler.
- Right position: The input requires a dry contact
Outputs
From the left side the outputs are numbered as pin 17 to pin 24. Each output is a dual pole relay with normally open, normally close and common available on the pin header.
The bottom four outputs each has a corresponding switch. This allows forwarding power from the power forwarding connector to the relay normally open and common on each output.
Relay ratings:
- Outputs: DPDT (Double Pole Double Throw). NO (Normal Open), NC (Normal Closed), COM (Common)
- Switched voltage: < 250VAC Rated (400VAC Max)
- Switched Voltage: < 2000 VA max
- Switching Current: < 8A rated (15A max, 4s)
Indicators
Each output has a LED which indicates if the output is active or not.
See here for for information on the TKIS-2 kit connections