[[File:IPLCM Outputs.PNG|thumb|400px|none|IP-LCM relays]]
 
[[File:IPLCM Outputs.PNG|thumb|400px|none|IP-LCM relays]]
  
 +
Relay 5 to 8 has a . This allows forwarding power from the power forwarding connector to the relay normally open and common on each output.
  
From the left side the outputs are numbered as pin 17 to pin 24. Each output is a dual pole relay with normally open, normally close and common available on the pin header. <br>
 
The bottom four outputs each has a corresponding switch. This allows forwarding power from the power forwarding connector to the relay normally open and common on each output.
 
  
 
+
'''Relay ratings''':
Relay ratings:
 
 
* '''Outputs''': DPDT (Double Pole Double Throw). NO (Normal Open), NC (Normal Closed), COM (Common)
 
* '''Outputs''': DPDT (Double Pole Double Throw). NO (Normal Open), NC (Normal Closed), COM (Common)
 
* '''Switched voltage''': < 250VAC Rated (400VAC Max)
 
* '''Switched voltage''': < 250VAC Rated (400VAC Max)

Revision as of 14:57, 10 January 2019

IP-LCM connectors

Inputs

Each of the 8 inputs has a corresponding selector switch, which selects between a dry closing contact or an active input.

  • Left position: The input requires an active signal, typically 5, 12V or 24VDC. The input is galvanic isolated with an opto-coupler. Polarity as indicated on the drawing.
  • Right position: The input requires a dry contact

Outputs

There are 8 relays, each with two sets of changeover contacts (DPDT). The changeover contacts, normally open (NO), normally closed (NC) and common (COM), are labeled in the silk print of the PCB.

IP-LCM relays

Relay 5 to 8 has a . This allows forwarding power from the power forwarding connector to the relay normally open and common on each output.


Relay ratings:

  • Outputs: DPDT (Double Pole Double Throw). NO (Normal Open), NC (Normal Closed), COM (Common)
  • Switched voltage: < 250VAC Rated (400VAC Max)
  • Switched Voltage: < 2000 VA max
  • Switching Current: < 8A rated (15A max, 4s)

Indicators

Each output has a LED which indicates if the output is active or not.