Actions

IP Desktop Station LED Indications: Difference between revisions

From Zenitel Wiki

No edit summary
No edit summary
Line 4: Line 4:
<br style="clear:both;" />
<br style="clear:both;" />
'''Blinking at 1 second intervals:'''<br/>
'''Blinking at 1 second intervals:'''<br/>
Station has no connection to the ICX-AlphaCom
Station cannot register to the server/controller


Possible reasons:
Possible reasons:
* No connection to Ethernet
* Invalid network settings (IP address and network mask) in the device
* Wrong AlphaCom IP address configured
* Wrong or missing account settings (Server IP, directory number, password..)
* Invalid IP address
* Failing to register due to missing license in the server
* No gateway or wrong gateway to the ICX-AlphaCom
* The server is offline
* Network or Server firewall is not blocking port 50001 (ICX-AlphaCom) or 5060 (Edge/SIP)
If the server is on a different subnet, check that
* A valid Default gateway is defined
 
'''No blinking:'''
 
Possible reasons:
* Station connected and registered to the ICX-AlphaCom
* Station not powered up (if no other LEDs are active)
 


'''Blinking at 5 second intervals:'''<br/>
'''Blinking at 5 second intervals:'''<br/>
{{Note| This LED behaviour only applies to INCA Desktop stations [[IP Desktop Master Station - 1008000000|1008000000]], [[IP Desktop Master Station - 1008001000|1008001000]] and [[IP Desktop Station with Video Display - 1408001635|1208001635]]}}
Station connected but NOT registered in the ICX-AlphaCom  
Station connected but NOT registered in the ICX-AlphaCom  


Line 18: Line 29:
* Station has not been programmed in AlphaPro
* Station has not been programmed in AlphaPro
* Missing IP Station license in the ICX-AlphaCom
* Missing IP Station license in the ICX-AlphaCom
'''No blinking:'''
Possible reasons:
* Station connected and registered to the ICX-AlphaCom
* Station not powered up (if no other LEDs are active)


[[Category:Station Indication LEDs]]
[[Category:Station Indication LEDs]]

Revision as of 11:04, 20 November 2020

Station LED

LED4 - Red 5mm LED on board rear side, also seen through front plate.

Station LED


Blinking at 1 second intervals:
Station cannot register to the server/controller

Possible reasons:

  • Invalid network settings (IP address and network mask) in the device
  • Wrong or missing account settings (Server IP, directory number, password..)
  • Failing to register due to missing license in the server
  • The server is offline
  • Network or Server firewall is not blocking port 50001 (ICX-AlphaCom) or 5060 (Edge/SIP)

If the server is on a different subnet, check that

  • A valid Default gateway is defined

No blinking:

Possible reasons:

  • Station connected and registered to the ICX-AlphaCom
  • Station not powered up (if no other LEDs are active)


Blinking at 5 second intervals:

Note icon This LED behaviour only applies to INCA Desktop stations 1008000000, 1008001000 and 1208001635


Station connected but NOT registered in the ICX-AlphaCom

Possible reasons:

  • Station has not been programmed in AlphaPro
  • Missing IP Station license in the ICX-AlphaCom