<br style="clear:both;" /> | <br style="clear:both;" /> | ||
'''Blinking at 1 second intervals:'''<br/> | '''Blinking at 1 second intervals:'''<br/> | ||
Station | Station cannot register to the server/controller | ||
Possible reasons: | Possible reasons: | ||
* | * Invalid network settings (IP address and network mask) in the device | ||
* Wrong | * Wrong or missing account settings (Server IP, directory number, password..) | ||
* | * Failing to register due to missing license in the server | ||
* | * The server is offline | ||
* Network or Server firewall is not blocking port 50001 (ICX-AlphaCom) or 5060 (Edge/SIP) | |||
If the server is on a different subnet, check that | |||
* A valid Default gateway is defined | |||
'''No blinking:''' | |||
Possible reasons: | |||
* Station connected and registered to the ICX-AlphaCom | |||
* Station not powered up (if no other LEDs are active) | |||
'''Blinking at 5 second intervals:'''<br/> | '''Blinking at 5 second intervals:'''<br/> | ||
{{Note| This LED behaviour only applies to INCA Desktop stations [[IP Desktop Master Station - 1008000000|1008000000]], [[IP Desktop Master Station - 1008001000|1008001000]] and [[IP Desktop Station with Video Display - 1408001635|1208001635]]}} | |||
Station connected but NOT registered in the ICX-AlphaCom | Station connected but NOT registered in the ICX-AlphaCom | ||
| Line 18: | Line 29: | ||
* Station has not been programmed in AlphaPro | * Station has not been programmed in AlphaPro | ||
* Missing IP Station license in the ICX-AlphaCom | * Missing IP Station license in the ICX-AlphaCom | ||
[[Category:Station Indication LEDs]] | [[Category:Station Indication LEDs]] | ||
Revision as of 11:04, 20 November 2020
Station LED
LED4 - Red 5mm LED on board rear side, also seen through front plate.
Blinking at 1 second intervals:
Station cannot register to the server/controller
Possible reasons:
- Invalid network settings (IP address and network mask) in the device
- Wrong or missing account settings (Server IP, directory number, password..)
- Failing to register due to missing license in the server
- The server is offline
- Network or Server firewall is not blocking port 50001 (ICX-AlphaCom) or 5060 (Edge/SIP)
If the server is on a different subnet, check that
- A valid Default gateway is defined
No blinking:
Possible reasons:
- Station connected and registered to the ICX-AlphaCom
- Station not powered up (if no other LEDs are active)
Blinking at 5 second intervals:
| This LED behaviour only applies to INCA Desktop stations 1008000000, 1008001000 and 1208001635 |
Station connected but NOT registered in the ICX-AlphaCom
Possible reasons:
- Station has not been programmed in AlphaPro
- Missing IP Station license in the ICX-AlphaCom