Difference between revisions of "INCA DualDisplay Station LED Indicators"
From Zenitel Wiki
(→Station LED) |
|||
Line 3: | Line 3: | ||
<br style="clear:both;" /> | <br style="clear:both;" /> | ||
'''Blinking at 1 second intervals:'''<br/> | '''Blinking at 1 second intervals:'''<br/> | ||
− | Station | + | Station cannot register to the server/controller |
Possible reasons: | Possible reasons: | ||
− | * | + | * Invalid network settings (IP address and network mask) in the device |
− | * Wrong | + | * Wrong or missing account settings (Server IP, directory number, password..) |
− | * | + | * Failing to register due to missing license in the server |
− | * | + | * The server is offline |
+ | * Network or Server firewall is not blocking port 50001 (ICX-AlphaCom) or 5060 (Edge/SIP) | ||
+ | If the server is on a different subnet, check that | ||
+ | * A valid Default gateway is defined | ||
− | ''' | + | '''No blinking:''' |
− | |||
Possible reasons: | Possible reasons: | ||
− | * Station | + | * Station connected and registered to the server/controller |
− | * | + | * Station not powered up (if no other LEDs are active) |
− | ''' | + | '''Blinking at 5 second intervals:'''<br/> |
+ | {{Note| This LED behaviour only applies in ICX-AlphaCom mode}} | ||
+ | Station connected but NOT registered in the ICX-AlphaCom | ||
Possible reasons: | Possible reasons: | ||
− | * Station | + | * Station has not been programmed in AlphaPro |
− | + | * Missing IP Station license in ICX-AlphaCom | |
[[Category:Station Indication LEDs]] | [[Category:Station Indication LEDs]] |
Latest revision as of 11:45, 20 November 2020
Station LED
Blinking at 1 second intervals:
Station cannot register to the server/controller
Possible reasons:
- Invalid network settings (IP address and network mask) in the device
- Wrong or missing account settings (Server IP, directory number, password..)
- Failing to register due to missing license in the server
- The server is offline
- Network or Server firewall is not blocking port 50001 (ICX-AlphaCom) or 5060 (Edge/SIP)
If the server is on a different subnet, check that
- A valid Default gateway is defined
No blinking:
Possible reasons:
- Station connected and registered to the server/controller
- Station not powered up (if no other LEDs are active)
Blinking at 5 second intervals:
Station connected but NOT registered in the ICX-AlphaCom
Possible reasons:
- Station has not been programmed in AlphaPro
- Missing IP Station license in ICX-AlphaCom