Actions

Difference between revisions of "Door Opening - Configuration example"

From Zenitel Wiki

(Map the relay to a Logical RCO)
Line 18: Line 18:
 
All Zenitel IP stations have an inbuilt relay. The relay must be mapped to a "Logical RCO" in the ICX-AlphaCom server. The mapping is done from AlphaPro, [[Exchange_%26_System_%28AlphaPro%29#RCO|Exchange & System > RCO]]. Here the logical RCO is assigned to a physical address.  The physical address is given as '''Station ID''' + '''Pin Number'''.
 
All Zenitel IP stations have an inbuilt relay. The relay must be mapped to a "Logical RCO" in the ICX-AlphaCom server. The mapping is done from AlphaPro, [[Exchange_%26_System_%28AlphaPro%29#RCO|Exchange & System > RCO]]. Here the logical RCO is assigned to a physical address.  The physical address is given as '''Station ID''' + '''Pin Number'''.
  
Open [[Exchange_%26_System_%28AlphaPro%29#RCO|Exchange & System > RCO]], and select a free RCO from the list on the left and click the '''Change''' button:
+
Open [[Exchange_%26_System_%28AlphaPro%29#RCO|Exchange & System > RCO]], and select a free RCO from the list to the left and click the '''Change''' button:
 
<table style="max-width:80%; border-style: double; border-color: #c7c7c7;">
 
<table style="max-width:80%; border-style: double; border-color: #c7c7c7;">
 
<tr style="rowspan:2;">
 
<tr style="rowspan:2;">

Revision as of 14:00, 5 May 2022

AI.png
DoorOpeningExample.png
Operator 120 in conversation with Door 106, pressing digit "6" to open the door

This article explains how to configure the Door Opening feature.

Door opening is a standard feature in the ICX-AlphaCom and AlphaCom XE. When an operator is in a conversation with a door station, the operator can press digit 6 to activate a relay. The relay will be pulsed for 3.5 seconds (configurable).

As an option, it is also possible to play a prerecorded message at the door, saying e.g. "The door is open, please enter".

Map the relay to a Logical RCO

All Zenitel IP stations have an inbuilt relay. The relay must be mapped to a "Logical RCO" in the ICX-AlphaCom server. The mapping is done from AlphaPro, Exchange & System > RCO. Here the logical RCO is assigned to a physical address. The physical address is given as Station ID + Pin Number.

Open Exchange & System > RCO, and select a free RCO from the list to the left and click the Change button:

DoorOpeningRCO.png
Setting the Edge Controller


Set the following parameters:

  • Description: Any text
  • RCO Type = Station
  • Station physical number: The physical number of the door station (Not the directory number)
  • Pin number: The output number related to the relay, normally "7" (see below)
RCO Change2.PNG


What Pin Numberto use depends on the station type:

For an overview of which devices are supporting RCOs and what pin numbers the use, see RCO - Remote Control Output

Note icon A Reset of the ICX-AlphaCom server is required for the RCO mapping configuration to take effect


Event Handler

We need to define who this event is for, and which output to activate. This is done using the Event Handler. Go to Exchange & System menu from the top menu in AlphaPro:

AlphaPro Exchange and System icon.png


From the Exchange & System window choose the Events button:

Exchange System Events.png


In the Event Actions window click the Insert button and create an event like this:

EventHandler Event2.PNG


This event is triggered when the operator dials digit 6 while in conversation with the door. Note that the Door Station is the owner of the event (here physical number 6). When Related To can be set to "All", meaning whoever in conversation with the door is allowed to dial digit 6 to open the door. In this example we have chosen to limit this access by selecting a single station; Operator with Directory number 120.

In the example above RCO 6 will be triggered when the Door Opening feature (digit 6) is pressed.

Finalization

Close all windows in AlphaPro and upload the database using the Send All button. Apply changes by restarting the server.

Note icon A Reset of the ICX-AlphaCom server is required for the RCO mapping configuration to take effect


AlphaPro Communication icon.png