Actions

Difference between revisions of "Door Opening - Configuration example"

From Zenitel Wiki

(Creating Event for Door Opening)
(Creating Event for Door Opening)
Line 69: Line 69:
 
* A group of stations: Set "When Related To" = '''Stations w/UDP'''
 
* A group of stations: Set "When Related To" = '''Stations w/UDP'''
  
In the example above RCO 6 will be pulsed for 3.5 sec when the Door Opening feature (digit 6) is pressed. The '''RCO Pulse Time''' can be change in the [[Exchange_%26_System_(AlphaPro)#Timers|Exchange & System > System > Timers tab]].
+
In the example above RCO 6 will be pulsed for 3.5 sec when the Door Opening feature (digit 6) is pressed on station number 120. The '''RCO Pulse Time''' can be change in the [[Exchange_%26_System_(AlphaPro)#Timers|Exchange & System > System > Timers tab]].
  
  

Revision as of 12:40, 11 May 2022

AI.png
DoorOpeningExample.png
Operator 120 in conversation with Door 106, pressing digit "6" to open the door

This article explains how to configure the Door Opening feature.

Door opening is a standard feature in the ICX-AlphaCom and AlphaCom XE. When an operator is in a conversation with a door station, the operator can press digit 6 to activate a relay. The relay will be pulsed for 3.5 seconds (configurable).

As an option, it is also possible to play a prerecorded message at the door, saying e.g. "The door is open, please enter".

Map the relay to a Logical RCO

All Zenitel IP stations have an inbuilt relay. The relay must be mapped to a "Logical RCO" in the ICX-AlphaCom server. The mapping is done from AlphaPro, Exchange & System > RCO. Here the logical RCO is assigned to a physical address. The physical address is given as Station ID + Pin Number.

Open Exchange & System > RCO, and select a free RCO from the list to the left and click the Change button:

DoorOpeningRCO.png
Default RCO configuration


Change the following parameters:

  • Description: Any text
  • RCO Type = Station
  • Station physical number: The physical number of the door station (Not the directory number)
  • Pin number: The output number related to the relay, normally "7" (see below)
DoorOpeningRCO2.png
Mapping logical RCO 6 to the relay of station 6 (106 - Entrance)

What Pin Number to use depends on the station type:

For an overview of which devices are supporting RCOs and what pin numbers they use, see Devices_supporting_RCOs

Note icon A Reset of the ICX-AlphaCom server is required for the RCO mapping configuration to take effect


Creating Event for Door Opening

In AlphaPro, open Users & Stations, and select the door station from the list to the left. Then select the button Events. Insert a new event with the following properties:

DoorOpeningEvent.png
Door Opening event


The When Related To field specifies who should be allowed to trigger the Door Opening feature. There are three options:

  • Any station: Set "When Related To" = All (default)
  • A specific station: Set "When Related To" = Directory Number, and in the "Id" field enter the directory number of the station that should be allowed to open the door (station 120 in the screenshot above)
  • A group of stations: Set "When Related To" = Stations w/UDP

In the example above RCO 6 will be pulsed for 3.5 sec when the Door Opening feature (digit 6) is pressed on station number 120. The RCO Pulse Time can be change in the Exchange & System > System > Timers tab.


Upload the database using the Send All button.

Note icon A Reset of the ICX-AlphaCom server is required for the RCO mapping configuration to take effect



Optional configuration

Automatic termination of the call after activation of door opening


Playing a prerecorded message at the door

Note icon This feature requires an Audio Messaging license


DoorOpeningMessage.png
Playing an audio message at the door

A prerecorded audio message can be played at the door when the operator activates the door lock, saying e.g. "The door is open, please enter".

A wav file must be uploaded to the ICX-AlphaCom server. Sample wav files can be found on the download page.

DoorOpeningUploadMessage.png
Uploading the wav file as Announcement Message (Message group 30) number 3 (Group index 3)


The action commands in the Door Opening event created in the previous section needs to be modified. In the example below station group 890 is used for dispatching the message. If this group is already in use, the below event must be modified to use a different group.

DoorOpeningEvent2.png
Door Opening event playing message 3 (8193) to group 890

The actions commands are:

RCO 6
$GRM L%1.dir L890 %chg(1,0)
IF %chg(1,0)
$GM L890 L8193 U1 U0 U0
ENDIF


Explanation:

  • When the Door Opening event goes ON:
    • Turn on RCO 6
    • Include ($GRM) the door station in station group 890
    • Play message 8193 to group 890
  • When the Door Opening event goes OFF 3.5 sec later:
    • Turn off RCO 6
    • Exclude ($GRM) the door station from station group 890