Actions

Difference between revisions of "Tamper switch"

From Zenitel Wiki

(For a single station)
Line 10: Line 10:
  
 
{{code2|$STM L110 L101 U145 'TAMPER CELL 10'}}
 
{{code2|$STM L110 L101 U145 'TAMPER CELL 10'}}
 +
 +
* $STM - Sendt Text Message
 +
* L110 - From 110
 +
* L101 * To 101
 +
* U145 - Priority level 145
 +
* TAMPER CELL 10 - Text
  
 
=== For all stations ===
 
=== For all stations ===

Revision as of 13:47, 1 December 2022

AEIPS.png

The IP Vandal Resistant Substation with TKIE has the possibility to be fitted with a tamper switch. Making it possible to raise an alarm if the station is dismounted from the backbox.

Tamper Switch
(1008091010)

Configuration

For a single station

In AlphaPro, create this event for the Tamper Switch, setting the substation as the event owner:

Event handler configuration


Action commands:

$STM L110 L101 U145 'TAMPER CELL 10'


  • $STM - Sendt Text Message
  • L110 - From 110
  • L101 * To 101
  • U145 - Priority level 145
  • TAMPER CELL 10 - Text

For all stations

In AlphaPro, create this event for the Tamper Switch, and configure UDP Group 8 as event owner:

Event handler configuration


Action commands:

$STM L%2.dir L101 U145 '%1.nam'


Verify that I/O 3 is set as an input

The IP Substation must have I/O number 3 defined as an input (default).

Advanced AlphaCom -> I/O Settings





Mounting

Mounting instruction on Tamper Switch for IP Vandal Resistant Substation TKIE

Step 1: Remove the two nylon nuts shown below

Tamper1.png


Step 2: Attach the supplied spacers

Tamper2.png


Step 3: Mount the tamper switch board

Tamper3.png


Step 4: Move the button GND wire from the the TKIE board to the tamper switch board

Tamper4.png


Tamper5.png


Step 5: Use the supplied wires to connect GND and Input 3 as shown below

Tamper6.png