Difference between revisions of "DISPLAY TEXT"
From Zenitel Wiki
Line 6: | Line 6: | ||
!style="background:#ffdead;" |AMC 06.00 | !style="background:#ffdead;" |AMC 06.00 | ||
|- | |- | ||
− | |colspan="5"|$DSPL L101 U18 0311 | + | |colspan="5"|$DSPL L101 U18 0311 'Line 1 text'<br\> |
− | + | $DSPL L101 U18 0312 'Line 2 text'<br\> | |
− | + | $DSPL L104 U23 0313 14 "Line 3 text on CRM "<br\> | |
− | + | $DSPL L104 U23 0313 54 "Line 4 text on CRM "<br\> | |
[[Dual Display Stations|Dual Display]] (from AMC 08.28 / 09.01):<br\> | [[Dual Display Stations|Dual Display]] (from AMC 08.28 / 09.01):<br\> | ||
− | + | 1. $DSPL L104 U11 33011302 'DAK line'<br\> | |
− | + | 2. $DSPL L104 U3 500400 ' '<br\> <br\> | |
IP station Custom Command (From AMC 10.30)<br\> | IP station Custom Command (From AMC 10.30)<br\> | ||
− | + | $DSPL L101 U4 60AB0812 ' ' > [[DIP#dicmd_-_Send_User_Defined_Command_.28.24DSPL.29|DIP message]] | |
|- | |- | ||
|colspan="5"|Send text and control characters to a station in a station dependent low level format.<br\> | |colspan="5"|Send text and control characters to a station in a station dependent low level format.<br\> |
Revision as of 15:08, 25 October 2011
DISPLAY_TEXT | 0x005A | 90 | AMC 06.00 | |
---|---|---|---|---|
$DSPL L101 U18 0311 'Line 1 text'<br\>
$DSPL L101 U18 0312 'Line 2 text'<br\> $DSPL L104 U23 0313 14 "Line 3 text on CRM "<br\> $DSPL L104 U23 0313 54 "Line 4 text on CRM "<br\> Dual Display (from AMC 08.28 / 09.01):<br\> 1. $DSPL L104 U11 33011302 'DAK line'<br\> 2. $DSPL L104 U3 500400 ' '<br\> <br\> IP station Custom Command (From AMC 10.30)<br\> $DSPL L101 U4 60AB0812 ' ' > DIP message | ||||
Send text and control characters to a station in a station dependent low level format.<br\>
The character set is ISO 8859 (for characters from 20 hex and above). The control characters used conforms to the TouchLine display format code for control of the display.<br\> AlphaNet: Message from remote exchange in order to display the enclosed text in a local station.<br\><br\> Note that the exchange updates the display frequently, and external control of the display will work only in special situations.<br\><br\> Dual Display:<br\> Example 1. Update text on DAK display line 02. legal values 01->64 (1-100 decimal)<br\> Example 2. Select (show) DAK page 04 on DualDisplay station with no arrow indication (last 00. Arrow down is visible if (last) number is 2 or more. Arrow up is visible if number is larger than the page number). | ||||
1 | NET_OBJ_REF<br\>{ECL_STATION} | Station displaying text.<br\>AlphaNet: B station in B exchange.<br\> Null value not allowed. | ||
2 | UINT1 | Length of text | ||
3 | Array of UINT1 | Text characters. |