Difference between revisions of "AlphaCom XE7"
From Zenitel Wiki
(→Specifications) |
|||
Line 1: | Line 1: | ||
[[Image:XE7.PNG|thumb|250px|AlphaCom XE7 Audio Server with HD Voice]] | [[Image:XE7.PNG|thumb|250px|AlphaCom XE7 Audio Server with HD Voice]] | ||
− | + | == Highlights == | |
+ | * Made to provide critical communication in any environment | ||
+ | * Supports 552 IP stations and 36 analog intercom stations | ||
+ | * Global networking and integration | ||
+ | * IP, SIP and analog station support | ||
+ | * Extended Software Options | ||
+ | * SIM card based software configuration and disaster recovery | ||
+ | * Fully compatible with any AlphaCom system | ||
+ | * Extended memory supports future expansion and new services | ||
+ | * High Quality Professional PA Broadcasting and Messaging services | ||
+ | * Security voice guidance for public safety and building security | ||
+ | * Auto-attendant functionality (Automatic voice supported switchboard) | ||
+ | * Voice supported call guidance | ||
− | == | + | ==Additional Documentation== |
− | + | For more documentation please see http://www.zenitel.com/product/alphacom-xe7 | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
== Installation == | == Installation == | ||
[[Image:XE7 installation.PNG|thumb|500px|left|Mounting AlphaCom XE7]] | [[Image:XE7 installation.PNG|thumb|500px|left|Mounting AlphaCom XE7]] | ||
− | |||
<br style="clear:both;" /> | <br style="clear:both;" /> | ||
== Connections == | == Connections == | ||
− | All cables are terminated to connectors on the backplane. The two-pair star wired intercom cables and single-pair telephone cables are connected using pluggable screw connectors | + | * All cables are terminated to connectors on the backplane. The two-pair star wired intercom cables and single-pair telephone cables are connected using pluggable screw connectors |
− | + | * Two RJ-45 Ethernet terminals are used for IP LAN, WAN, Internet and AlphaNet IP communication. Eth0 is also used for programming | |
− | Two RJ-45 Ethernet terminals are used for IP LAN, WAN, Internet and AlphaNet IP communication. Eth0 is also used for programming | + | * The serial ports with RS232 and RS422/RS485 interfaces are used for connecting to equipment using these protocols |
− | + | * There are two inputs for clean contacts on the RCI connectors which can execute programmable functions. The 12 RCOs are connected to optional [[MRBD]] relay boards and can be programmed to execute functions such as door control | |
− | + | * [[Physical number 5 and 6 (AlphaCom E7)|Connectors 5 and 6]] on the first ASLT line board are enabled for program distribution. Additional programs can be connected by substituting line boards with AGA boards with 6 programs per board | |
− | + | * The server is normally powered from the mains via a 24 VAC transformer. Battery backup power can be connected to the 24 VDC input plug. | |
− | Connectors 5 and 6 on the first ASLT line board are enabled for program distribution. Additional programs can be connected by substituting line boards with AGA boards with 6 programs per board | + | [[File:AC E7 Connection to AlphaCom E7.jpg|thumb|left|500px]] |
− | + | <br style="clear:both;" /> | |
− | The server is normally powered from the mains via a 24 VAC transformer. Battery backup power can be connected to the 24 VDC input plug. | ||
− | == | + | == Related article == |
− | + | * [[Physical number 5 and 6 (AlphaCom E7)|Physical number 5 and 6]] | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
[[Category:Hardware]] | [[Category:Hardware]] | ||
[[Category:AlphaCom XE Exchanges]] | [[Category:AlphaCom XE Exchanges]] |
Revision as of 07:56, 7 August 2015
Highlights
- Made to provide critical communication in any environment
- Supports 552 IP stations and 36 analog intercom stations
- Global networking and integration
- IP, SIP and analog station support
- Extended Software Options
- SIM card based software configuration and disaster recovery
- Fully compatible with any AlphaCom system
- Extended memory supports future expansion and new services
- High Quality Professional PA Broadcasting and Messaging services
- Security voice guidance for public safety and building security
- Auto-attendant functionality (Automatic voice supported switchboard)
- Voice supported call guidance
Additional Documentation
For more documentation please see http://www.zenitel.com/product/alphacom-xe7
Installation
Connections
- All cables are terminated to connectors on the backplane. The two-pair star wired intercom cables and single-pair telephone cables are connected using pluggable screw connectors
- Two RJ-45 Ethernet terminals are used for IP LAN, WAN, Internet and AlphaNet IP communication. Eth0 is also used for programming
- The serial ports with RS232 and RS422/RS485 interfaces are used for connecting to equipment using these protocols
- There are two inputs for clean contacts on the RCI connectors which can execute programmable functions. The 12 RCOs are connected to optional MRBD relay boards and can be programmed to execute functions such as door control
- Connectors 5 and 6 on the first ASLT line board are enabled for program distribution. Additional programs can be connected by substituting line boards with AGA boards with 6 programs per board
- The server is normally powered from the mains via a 24 VAC transformer. Battery backup power can be connected to the 24 VDC input plug.