PULSE_RCO 0x001B 27 AMC 05.00
$PULS W1 W500
Generate a pulse with the defined length. <br\>Note: NOT supported for exchange RCO s. Does not work in RIO 2.xx due to software bug.
1 UINT2 Output pin number
2 UINT2 Pulse length. Unit = 10ms
Response: PULSE_RCO_OK, PULSE_RCO_FAILED